Answers are grounded in this paper and cite their sources.
To check the noise levels in the industry and commercial areas in Kumasi Metropolitan area, bus terminals and timber industries were selected and investigated. Measurements of daytime noise levels was carried out in three bus terminals and two timber industries, using DT-8852 Precision digital sound level meter. The three bus terminals were the Kwame Nkrumah University of Science and Technology (KNUST) Junction, Anloga Junction and Kejetia. The results showed that they had daytime noise levels of 78.8 dBA, 72.1 dBA and 78.3 dBA respectively. For the two timber industries, company A and B, their day time noise levels were 84.1 dBA and 82.4 dBA. Comparing the results with the Ghana Environmental Protection Agency (EPA) standards, the three bus terminals had their day time noise levels exceeding the permissible levels by 8.8 dBA, 2.1 dBA and 8.3 dBA respectively, while the timber industries had their day time noise levels exceeding the permissible levels by 14.1 dBA and 12.4 dBA respectively. The levels are alarming therefore it is recommended that the public be made aware of the adverse effects of noise pollution and necessary law enforcement steps taken to check it.
No takes yet. Share an insight, caveat, or question.
E.O et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: