Key result
Transcatheter aortic valve implantation with the Lotus valve was associated with a higher rate of permanent pacemaker requirement at discharge compared to the Sapien XT valve.
Why the study?
Does the Lotus valve compared to the Edwards Sapien XT valve alter electrophysiological parameters and pacemaker requirement in patients undergoing TAVI?
Observational (n=55)
Does the Lotus valve compared to the Edwards Sapien XT valve alter electrophysiological parameters and pacemaker requirement in patients undergoing TAVI?
The Lotus valve is associated with a greater impact on atrioventricular conduction systems and a trend toward higher pacemaker requirement compared to the Sapien XT valve, though it has less paravalvular leakage.
Answers are grounded in this paper and cite their sources.
May favor Sapien XT to limit pacemaker risk; leaves open randomized confirmation of comparative safety.
BACKGROUND: The purpose of this study is to assess the electrocardiographic and electrophysiological parameters of conduction abnormalities in patients undergoing transcatheter aortic valve implantation (TAVI) due to severe aortic valve stenosis. METHODS: The study included 55 patients who underwent TAVI using either the Boston Scientific Lotus (n:25) (Boston Scientific, Natick, MA, USA) or Edwards Sapien XT (n:30) (Edwards Lifesciences, Irvine, CA, USA) prostheses. An electrophysiological study (EPS) was performed in the catheterization room immediately before the initial balloon valvuloplasty and immediately after prosthesis implantation. RESULTS: QRS duration and His-bundle to His-ventricle (HV) intervals, which were similar between the two groups before the procedure, were found to be significantly higher in the Lotus valve group postprocedure. Permanent pacemakers (PPMs) were required more frequently in the Lotus group than in the Sapien XT group at discharge (24.0% vs 6.7%, P = 0.07). With the exception of a higher prevalence of paravalvular leakage (P < 0.001) in patients undergoing Sapien XT implantation, other clinical outcomes were similar between the two groups. Multiple regression analysis revealed that baseline atrioventricular (AV) conduction disorders and HV intervals after the procedure were independently associated with PPM implantation after TAVI. CONCLUSION: In this first study comparing the findings of EPS and electrocardiography, the impact of the Lotus valve on AV conduction systems was greater than that of the Sapien XT. However, the need for PPM was higher in the Lotus valve than in the Sapien XT. PPM requirement is related to valve design; it may decrease with reduced frame height and metal burden in novel valve systems.
No takes yet. Share an insight, caveat, or question.
Eksik et al. (2016) conducted an observational in severe aortic valve stenosis (n=55). Boston Scientific Lotus valve vs. Edwards Sapien XT valve was evaluated on Permanent pacemaker requirement at discharge (p=0.07). Transcatheter aortic valve implantation with the Lotus valve was associated with a higher rate of permanent pacemaker requirement at discharge compared to the Sapien XT valve.
Synapse has enriched 10 related papers. Consider them for comparative context: