Key result
Lotus valve matches ES3 in device success but triples new pacemaker risk in TAVI.
Why the study?
New-generation transcatheter heart valves have been developed to reduce complications of TAVI, but comparative data between the repositionable Lotus and balloon-expandable Edwards Sapien 3 valves were lacking.
Does transfemoral TAVI with the Lotus valve compared to the Edwards Sapien 3 valve improve procedural and 30-day outcomes in patients with severe symptomatic aortic stenosis?
Cohort (n=315)
Yes
Does transfemoral TAVI with the Lotus valve compared to the Edwards Sapien 3 valve improve procedural and 30-day outcomes in patients with severe symptomatic aortic stenosis?
Both Lotus and ES3 valves provide high device success and low paravalvular leak rates in TAVI, though the Lotus valve is associated with a significantly higher risk of new pacemaker implantation.
Answers are grounded in this paper and cite their sources.
Lotus valve associated with higher pacemaker risk; should not yet change practice and leaves open need for randomized confirmation.
BACKGROUND: New-generation transcatheter heart valves have been developed to reduce complications of transcatheter aortic valve implantation (TAVI). With this study we sought to compare procedural and 30-day outcomes of the new-generation repositionable Boston Scientific Lotus (Lotus) and the balloon-expandable Edwards Sapien 3 (ES3) transcatheter heart valves. METHODS: A total of 315 patients with severe symptomatic aortic stenosis undergoing transfemoral TAVI with Lotus or ES3 included in two large Italian registries were considered for this analysis. After propensity matching, 93 matched pairs of patients were included. Outcomes were evaluated according to Valve Academic Research Consortium-2 definition at discharge and 30 days. RESULTS: There were no differences in baseline characteristics, except for lower mean aortic gradient and larger mean aortic annulus in the ES3-treated patients. Valve Academic Research Consortium-2 defined device success was high and comparable between groups (97.8 for Lotus vs. 98.9% for ES3, P = 0.09). The frequency of moderate/severe paravalvular leak was low and similar for both devices (2.2 vs. 1.1%, P = 0.10). At 30 days, both groups showed low all-cause mortality (5.4 vs. 1.1%, P = 0.10) and rates of disabling stroke (3.2 vs. 1.1%, P = 0.31). New pacemaker implantation was more common after Lotus deployment (31.7 vs. 10.5%, P < 0.001). CONCLUSION: Transfemoral TAVI with both Lotus and ES3 resulted in favorable clinical and hemodynamic procedural and 30-day outcomes. Rates of significant paravalvular leak were low with both devices. The Lotus valve was associated with higher risk of pacemaker implantation.
No takes yet. Share an insight, caveat, or question.
Fovino et al. (2018) conducted a cohort in severe symptomatic aortic stenosis (n=315). Boston Scientific Lotus transcatheter heart valve vs. Edwards Sapien 3 (ES3) transcatheter heart valve was evaluated on Device success (Valve Academic Research Consortium-2 definition) (p=0.09). Transfemoral TAVI with the Lotus valve showed comparable device success to the ES3 valve but a higher risk of new pacemaker implantation.