Key result
Device-derived respiratory data from adaptive servo-ventilation, including increased apnea-hypopnea index 10 days prior, significantly predicted early cardiac decompensation in heart failure.
Why the study?
Cardiac decompensation worsens prognosis in heart failure, but reliable predictive methods are lacking. This study aimed to identify sleep-disordered breathing patterns that may predict early decompensation.
Does monitoring device-derived respiratory data during adaptive servo-ventilation predict early clinical cardiac decompensation in patients with heart failure and sleep-disordered breathing?
Observational (n=43)
Does monitoring device-derived respiratory data during adaptive servo-ventilation predict early clinical cardiac decompensation in patients with heart failure and sleep-disordered breathing?
Device-derived respiratory data from ASV therapy, such as increased AHI and inspiratory pressure, may serve as an early warning system for impending cardiac decompensation in heart failure patients.
Answers are grounded in this paper and cite their sources.
May support early ASV monitoring for HF decompensation alerts; hypothesis-generating and requires prospective validation.
Summary Cardiac decompensation is associated with worse prognosis in patients with heart failure. Reliable methods to predict cardiac decompensation events are not yet available. Sleep‐disordered breathing (SDB) is a frequent comorbidity in heart failure, and it has been shown to correlate with heart failure severity. This prospective observational trial investigated SDB characteristics in patients with heart failure with the aim to identify patterns that may predict early cardiac decompensation. Patients with heart failure with diagnosed SDB and hospitalised for cardiac decompensation were prospectively enrolled and treated with adaptive servo‐ventilation (ASV). SDB characteristics, daily body weight and clinical cardiac decompensation events were collected over a 1‐year follow‐up. Clinical events were categorised by an independent clinical event committee. A total of 43 patients were enrolled (81% male, mean [SD] age 71 [11] years, body mass index 30 kg/m 2 , 95% New York Heart Association function class III or IV, mean [SD] left ventricular ejection fraction 37% [11%], median apnea–hypopnoea index [AHI] of 37 events/h). A total of 48 cardiac decompensation events were recorded during the 1‐year study period. Respiratory rate was found to be significantly lower in patients with cardiac decompensation. The AHI and applied inspiratory pressure ASV‐device support were significantly increased 10 days before a clinical cardiac decompensation event. Device usage was also found to be significantly decreased 2 nights before cardiac decompensation. Device‐derived respiratory data in ASV therapy devices for SDB may therefore serve as a monitoring tool to predict early clinical cardiac decompensation events. Prediction and avoidance of cardiac decompensation, in turn, may attenuate serious health consequences in patients with heart failure.
No takes yet. Share an insight, caveat, or question.
Fox et al. (2022) conducted an observational in Heart failure with sleep-disordered breathing (n=43). Adaptive servo-ventilation (ASV) derived respiratory data was evaluated on Clinical cardiac decompensation events. Device-derived respiratory data from adaptive servo-ventilation, including increased apnea-hypopnea index 10 days prior, significantly predicted early cardiac decompensation in heart failure.
Synapse has enriched 10 related papers. Consider them for comparative context: