Why the study?
Does multiplane TEE improve diagnostic accuracy for valvular perforation compared to TTE in patients with active infective endocarditis?
Does multiplane TEE improve diagnostic accuracy for valvular perforation compared to TTE in patients with active infective endocarditis?
Multiplane TEE is superior to TTE for detecting valvular perforation in active infective endocarditis and should be performed directly in hemodynamically unstable patients.
Answers are grounded in this paper and cite their sources.
TTE's low sensitivity warrants caution for valvular perforation in active IE; leaves open whether TEE-first improves outcomes.
We evaluated the diagnostic accuracy of transthoracic and multiplane transesophageal echocardiography (TTE and TEE, respectively) for assessing valvular perforation during active infective endocarditis by correlating the results of TTE and TEE with anatomic findings of 88 valves examined at surgery or autopsy. Compared with TEE, TTE has a low diagnostic sensitivity in the detection of this complication and, in the presence of hemodynamic instability, multiplane TEE should be performed directly.
No takes yet. Share an insight, caveat, or question.
Castro et al. (2000) studied this question.