The accuracy of population-based methods and of Bayesian analysis to predict individual digoxin pharmacokinetic variables have been evaluated by their ability to predict a measured peak and trough serum digoxin concentration. We studied 13 digitalized patients (three women) whose mean (range) age and weight was 65.8 (60-78) years and 76.6 (68-101.6) kg and who had stable renal function. The population-based methods (using a clearance of 48.87 + 0.87 x creatinine clearance in ml/h/kg and volume of distribution, in litres, of either 7.3 x weight (kg) or 269 + 3.12 x creatinine clearance) were more than adequate for clinical purposes. The mean prediction errors of a measured steady-state peak concentration from these two population methods were -0.074 and 0.013 microgram/l respectively, whilst those of a measured trough concentration were -0.058 and 0.005 microgram/l. Bayesian analysis, using a sample drawn 11 h after the dose on day five of therapy, gave overall the least biased and most precise of the revised estimates. The mean prediction errors of peak and trough values using this sample were 0.069 and -0.005 microgram/l respectively. As expected, the closer the sample was drawn to the time of the trough concentration the more precise were the Bayesian-derived predictions. The value of the Bayesian technique to individualize digoxin doses could not be validated because it was not possible to distinguish between this and the population methods.(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Chrystyn et al. (1991) conducted an observational in Atrial fibrillation (n=13). Bayesian analysis of digoxin pharmacokinetics vs. Population-based pharmacokinetic methods was evaluated on Mean prediction error of measured steady-state peak and trough serum digoxin concentrations. Bayesian analysis using a day-5 11-h sample gave peak and trough digoxin prediction errors of 0.069 and -0.005 ug/l, comparable to population-based methods.
Synapse has enriched 10 related papers. Consider them for comparative context: