Pulmonary vein stenosis can still occur after atrial fibrillation ablation using newer circular decapolar catheters designed to deliver energy outside the pulmonary veins.
Answers are grounded in this paper and cite their sources.
Pulmonary vein stenosis may still occur after AF ablation with modern catheters; this case leaves open true incidence and surveillance needs.
Pulmonary vein stenosis is less common with the newer techniques of atrial fibrillation ablation but must always be considered especially in symptomatic patients. This 54-year-old man presented with effort dyspnoea. He had a background of symptomatic paroxysmal atrial fibrillation and had undergone two prior ablation procedures using Pulmonary Vein Ablation Catheter Medtronic catheters. These circular decapolar catheters are designed to deliver radiofrequency well outside the pulmonary veins. Energy delivered was a maximum of 10 W per electrode which is roughly equivalent to 30 W from a conventional irrigated tip ablation catheter. Computed tomography clearly demonstrates tight stenosis of the left upper pulmonary vein ( Panels A and C ) and transoesophageal echocardiography ( Panels B and D ) shows the haemodynamic consequences with high-velocity flow on Doppler reaching 280 cm/s. Conflict of interest: none declared.