Why the study?
Does cardiac troponin T measurement improve diagnostic efficiency compared to CK-MB and myoglobin in patients with suspected acute coronary syndromes?
Does cardiac troponin T measurement improve diagnostic efficiency compared to CK-MB and myoglobin in patients with suspected acute coronary syndromes?
Cardiac troponin T is diagnostically equivalent to CK-MB and superior to myoglobin for assessing suspected acute coronary syndromes, supporting its use in routine clinical practice.
Answers are grounded in this paper and cite their sources.
May support troponin T use for suspected ACS diagnosis; leaves open prospective validation before practice change.
OBJECTIVE: To assess the diagnostic efficiency of the third generation cardiac troponin T assay in routine clinical practice. DESIGN: Prospective observational study of unselected consecutive admissions. SETTING: Multicentre study in 43 teaching and non-teaching hospitals in 13 countries. SUBJECTS: 1105 hospital admissions, median age 67 years (range 15-96 years, 63.7% male) with suspected acute coronary syndromes (72.3% of cases) or other non-specific symptoms where cardiac disease required exclusion (27.7%). INTERVENTIONS: Over the study period, myoglobin, creatine kinase MB isoenzyme (CK-MB), and cardiac troponin T where measured in parallel with conventional diagnostic tests. Final diagnostic classification involved standard ECG changes and CK-MB mass exceeding 5.0 microg/l. MAIN OUTCOME MEASURES: Diagnostic efficiency was assessed by receiver operator characteristic curve analysis including and excluding patients with unstable angina. RESULTS: Measurement of cardiac troponin T was diagnostically equivalent to CK-MB and both were better than myoglobin, with areas under the curve at 12 hours of 0.94, 0.99, and 0.80, respectively. Diagnostic criteria using CK-MB were inadequate and showed bias when patients with unstable angina were included. Elevations of cardiac troponin T did not occur when cardiac disease could be categorically excluded but were found in clinical conditions other than suspected acute coronary syndromes. CONCLUSIONS: CK-MB is unsuitable as a diagnostic gold standard even at the proposed lower threshold. A lower cut off for cardiac troponin T of 0.05 microg/l should be used for diagnosis of acute myocardial infarction. Diagnosis of acute myocardial infarction cannot be made solely on the basis of a cardiac troponin T result.
No takes yet. Share an insight, caveat, or question.
Paul Collinson (2003) studied this question.