Key result
Severe myocardial iron loading is present in ~96% of thalassemia major patients developing heart failure.
Cohort (n=3,095)
Yes
Answers are grounded in this paper and cite their sources.
International survey demonstrates that severe myocardial iron overload predicts heart failure and death in beta-thalassemia major, highlighting the clinical prognostic utility of magnetic resonance.
Accumulation of myocardial iron is the cause of heart failure and early death in most transfused thalassemia major patients. T2* cardiovascular magnetic resonance provides calibrated, reproducible measurements of myocardial iron. However, there are few data regarding myocardial iron loading and its relation to outcome across the world. A survey is reported of 3,095 patients in 27 worldwide centers using T2* cardiovascular magnetic resonance. Data on baseline T2* and numbers of patients with symptoms of heart failure at first scan (defined as symptoms and signs of heart failure with objective evidence of left ventricular dysfunction) were requested together with more detailed information about patients who subsequently developed heart failure or died. At first scan, 20.6% had severe myocardial iron (T2*≤ 10 ms), 22.8% had moderate myocardial iron (T2* 10-20 ms) and 56.6% of patients had no iron loading (T2*>20 ms). There was significant geographical variation in myocardial iron loading (24.8-52.6%; P<0.001). At first scan, 85 (2.9%) of 2,915 patients were reported to have heart failure (81.2% had T2* <10 ms; 98.8% had T2* <20 ms). During follow up, 108 (3.8%) of 2,830 patients developed new heart failure. Of these, T2* at first scan had been less than 10 ms in 96.3% and less than 20 ms in 100%. There were 35 (1.1%) cardiac deaths. Of these patients, myocardial T2* at first scan had been less than 10 ms in 85.7% and less than 20 ms in 97.1%. Therefore, in this worldwide cohort of thalassemia major patients, over 43% had moderate/severe myocardial iron loading with significant geographical differences, and myocardial T2* values less than 10 ms were strongly associated with heart failure and death.
No takes yet. Share an insight, caveat, or question.
Carpenter et al. (2013) conducted a cohort in β-thalassemia major (n=3,095). Severe myocardial iron loading (T2 <10 ms on cardiovascular magnetic resonance) vs. Moderate (T2 10-20 ms) or no myocardial iron loading (T2 >20 ms) was evaluated on New-onset heart failure and cardiac death during follow-up. Severe myocardial iron loading (T2 <10 ms) was present in 96.3% of thalassemia major patients who developed new heart failure and 85.7% of those who suffered cardiac death.
Synapse has enriched 10 related papers. Consider them for comparative context: