Key result
The simultaneous sequential strategy for the modified maze procedure restored sinus rhythm in 88.9% of patients with persistent atrial fibrillation and mitral valve disease.
Why the study?
Does a simultaneous sequential strategy improve sinus rhythm restoration in patients with persistent atrial fibrillation undergoing mitral valve surgery?
Observational (n=27)
Does a simultaneous sequential strategy improve sinus rhythm restoration in patients with persistent atrial fibrillation undergoing mitral valve surgery?
A simultaneous sequential strategy adding a right-sided maze only if atrial fibrillation persists after a left-sided maze during mitral surgery achieves a high rate of sinus rhythm restoration comparable to standard bi-atrial maze procedures.
Answers are grounded in this paper and cite their sources.
Supports sequential maze during mitral surgery with persistent AF; hypothesis-generating and requires randomized confirmation before practice change.
BACKGROUND: We assessed whether the simultaneous sequential strategy could (1) achieve additional sinus restoration for those patients who were not in sinus rhythm while coming off bypass after modified left maze procedure and (2) attain the same long-term success rates as the bi-atrial maze procedure in patients with persistent atrial fibrillation (AF) and mitral valve disease. MATERIALS AND METHODS: Twenty-seven consecutive patients - ten men and 17 women with a mean age of 52 +/- 13 years, all with persistent AF and mitral valve disease - underwent the modified maze procedure with the simultaneous sequential strategy. In the first phase, the modified left atrial maze operation was carried out with concomitant valvular surgery; the right side maze operation was subsequently carried out as a second phase of the sequential strategy only if AF re-appeared following the spontaneous restoration of heart beats during the operation. RESULTS: Twenty patients (74.1%) underwent the left atrial maze procedure only, and seven patients (25.9%) required the subsequent right atrial maze procedure as part of the sequential strategy. At a mean follow-up of 15.1 +/- 7.7 months, six of the 27 patients (22.2%) who underwent additional right atrial maze procedure had restored sinus rhythm. At a mean follow-up of 17.8 +/- 7.3 months, 24 of the 27 patients (88.9%) had restored sinus rhythm and 22 patients (81.5%) had restored bi-atrial transport function (right atrial filling fraction: 40.8 +/- 11.7%; left atrial filling fraction: 22.9 +/- 8.1%) after application of the sequential strategy. CONCLUSIONS: Compared with modified left atrial maze procedure, the application of the simultaneous sequential strategy successfully restored sinus rhythm in an additional 22.2% of patients with persistent AF. The overall sinus conversion rate of 88.9% was comparable with that of the standard bi-atrial maze procedure.
No takes yet. Share an insight, caveat, or question.
Chang et al. (2006) conducted an observational in Persistent atrial fibrillation and mitral valve disease (n=27). Simultaneous sequential strategy (modified left atrial maze followed by right atrial maze if needed) vs. Modified left atrial maze procedure alone was evaluated on Restoration of sinus rhythm. The simultaneous sequential strategy for the modified maze procedure restored sinus rhythm in 88.9% of patients with persistent atrial fibrillation and mitral valve disease.
Synapse has enriched 10 related papers. Consider them for comparative context: