Why the study?
Does valve replacement using mounted aortic heterografts provide good valve function and survival in patients requiring valve replacement?
Does valve replacement using mounted aortic heterografts provide good valve function and survival in patients requiring valve replacement?
Early clinical experience with mounted aortic heterograft valves demonstrated acceptable short-term valve function in most survivors, despite occurrences of severe complications such as infection and cusp disruption.
Answers are grounded in this paper and cite their sources.
Short-term heterograft valve replacement appears feasible in small series; leaves open durability, infection risk, and broader applicability.
This report concerns our clinical experience with mounted aortic heterograft valves. There were nine patients, four males and five females, ranging in age from 5 to 65 years. The mitral valve was replaced in eight patients (concomitant tricuspid replacement in one), and the aortic valve in one instance. There was one operative death in a child with complete atrioventricularis communis (AV canal). One patient died after Starr valve replacement of a heterograft which had become infected and obstructed four months after implantation. Another patient developed late valve incompetence due to disruption of a cusp, and the heterograft was successfully replaced with a Starr valve. The seven current survivors, six with heterografts, have good valve function. The follow-up period extends from 3 to 13 months.
No takes yet. Share an insight, caveat, or question.
Katsuji Kubo (1971) studied this question.