Why the study?
Valve-in-Valve TAVR is a potential solution for malfunctioning surgical aortic valve prostheses, but limited data exist regarding its use in Perceval valves.
Does Valve-in-Valve TAVR provide safe and effective hemodynamic and clinical outcomes in patients with degenerated Perceval sutureless surgical aortic valve bioprostheses?
Does Valve-in-Valve TAVR provide safe and effective hemodynamic and clinical outcomes in patients with degenerated Perceval sutureless surgical aortic valve bioprostheses?
This systematic review demonstrates that Valve-in-Valve TAVR using either balloon-expanding or self-expanding valves is a feasible and effective option with favorable hemodynamics for treating degenerated Perceval sutureless surgical aortic valves in high-risk elderly patients.
Answers are grounded in this paper and cite their sources.
VIV TAVR may be feasible for degenerated Perceval valves in selected patients; leaves open need for prospective outcome and durability data.
Background: Valve-in-Valve (VIV) transcatheter aortic valve replacement (TAVR) is a potential solution for malfunctioning surgical aortic valve prostheses, though limited data exist for its use in Perceval valves. Methods: searches were performed on PubMed and Scopus up to 31 July 2023, focusing on case reports and series addressing VIV replacement for degenerated Perceval bioprostheses. Results: Our analysis included 57 patients from 27 case reports and 6 case series. Most patients (68.4%) were women, with a mean age of 76 ± 4.4 years and a mean STS score of 6.1 ± 4.3%. Follow-up averaged 9.8 ± 8.9 months, the mean gradient reduction was 15 ± 5.9 mmHg at discharge and 13 ± 4.2 mmHg at follow-up. Complications occurred in 15.7% of patients, including atrioventricular block III in four patients (7%), major bleeding or vascular complications in two patients (3.5%), an annular rupture in two patients (3.5%), and mortality in two patients (3.5%). No coronary obstruction was reported. Balloon-expanding valves were used in 61.4% of patients, predominantly the Sapien model. In the self-expanding group (38.6%), no valve migration occurred, with a permanent pacemaker implantation rate of 9%, compared to 5.7% for balloon-expanding valves. Conclusions: VIV-TAVR using both balloon-expanding and self-expanding technologies is feasible after the implantation of Perceval valves; however, it should be performed by experienced operators with experience both in TAVR and VIV procedures.
No takes yet. Share an insight, caveat, or question.
Owais et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: