Why the study?
Polymers represent a promising alternative to mechanical and biological materials for artificial heart valves, prompting evaluation of poly(styrene-block-isobutylene-block-styrene) properties.
Does poly(styrene-block-isobutylene-block-styrene) (SIBS) demonstrate superior material and hemocompatibility properties compared to polytetrafluoroethylene for manufacturing heart valve leaflets in preclinical models?
Does poly(styrene-block-isobutylene-block-styrene) (SIBS) demonstrate superior material and hemocompatibility properties compared to polytetrafluoroethylene for manufacturing heart valve leaflets in preclinical models?
SIBS is a highly hemocompatible material with lower calcification tendency than Gore-tex, showing promise for polymeric heart valve leaflets, though its mechanical strength needs improvement.
SIBS may reduce calcification in polymeric valves; hypothesis-generating given inferior strength in this animal study only.
Superior polymers represent a promising alternative to mechanical and biological materials commonly used for manufacturing artificial heart valves. The study is aimed at assessing poly(styrene-block-isobutylene-block-styrene) (SIBS) properties and comparing them with polytetrafluoroethylene (Gore-texTM, a reference sample). Surface topography of both materials was evaluated with scanning electron microscopy and atomic force microscopy. The mechanical properties were measured under uniaxial tension. The water contact angle was estimated to evaluate hydrophilicity/hydrophobicity of the study samples. Materials’ hemocompatibility was evaluated using cell lines (Ea.hy 926), donor blood, and in vivo. SIBS possess a regular surface relief. It is hydrophobic and has lower strength as compared to Gore-texTM (3.51 MPa vs. 13.2/23.8 MPa). SIBS and Gore-texTM have similar hemocompatibility (hemolysis, adhesion, and platelet aggregation). The subcutaneous rat implantation reports that SIBS has a lower tendency towards calcification (0.39 mg/g) compared with Gore-texTM (1.29 mg/g). SIBS is a highly hemocompatible material with a promising potential for manufacturing heart valve leaflets, but its mechanical properties require further improvements. The possible options include the reinforcement with nanofillers and introductions of new chains in its structure.