Why the study?
The study aimed to explore a cuffless approach for estimating systolic and diastolic blood pressure using photoplethysmogram and electrocardiogram signals.
The proposed DDCCR-Net framework provides a highly accurate solution for cuffless blood pressure estimation using PPG and ECG signals, meeting international measurement standards.
Cautious adoption advised pending trials; leaves open prospective validation of dual-modal networks for continuous BP monitoring.
This study aims to explore a cuffless approach for estimating systolic blood pressure (SBP) and diastolic blood pressure (DBP) using photoplethysmogram (PPG) and electrocardiogram (ECG) signals. To this end, we propose a novel framework based on dual-modal dynamic convolutions and correlation-based residual networks (ResNet), DDCCR-Net. The framework first extracts low-level features from the PPG and ECG modalities using dynamic convolution and a channel-wise adaptive mechanism and combines dual-modal dynamic convolutions with learnable weights, this allows the model to effectively capture the complex dynamic variations in physiological signals. Then, a residual network is employed to facilitate better feature propagation in the dynamic convolution module, enabling the model to capture higher-level dependencies in the signals and generate more expressive features. Finally, a correlation module is introduced to further learn inter-feature relationships, enhancing the accuracy of the predictive features, which are then utilized for the final predictions. The proposed framework was validated on the VitalDB dataset, with experimental results demonstrating superior performance in both SBP and DBP estimation tasks (SBP MAE ± SD: 3.91 ± 5.96 mmHg, DBP MAE ± SD: 2.28 ± 3.79 mmHg), outperforming existing baseline models and meeting international blood pressure measurement standards such as those of the Association for the Advancement of Medical Instrumentation (AAMI) and the British Hypertension Society (BHS). Furthermore, fine-tuning techniques were applied to improve model performance, and its cross-dataset generalization capability was assessed using the MIMIC-III dataset. Overall, the proposed DDCCR-Net framework provides a highly accurate and versatility applicable solution for cuffless blood pressure estimation.
No takes yet. Share an insight, caveat, or question.
Li et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: