Why the study?
Does selective slow pathway ablation cause complete heart block in patients with prolonged PR intervals undergoing ablation for AV reentry tachycardia?
Population
7 patients with prolonged PR intervals undergoing catheter ablation for AV reentry tachycardia, mean age 66…
Design
Case_series
Authors
Loading...
May support safe selective slow pathway ablation in prolonged PR intervals; leaves open confirmation in larger prospective studies.
Does selective slow pathway ablation cause complete heart block in patients with prolonged PR intervals undergoing ablation for AV reentry tachycardia?
Selective slow pathway ablation can be performed safely without causing complete heart block in patients with prolonged PR intervals, though careful catheter positioning at anterior sites is required.
Natale et al. (1997) studied this question.