Why the study?
Higher post-procedural transprosthetic gradients are more common after ViV-TAVR than after native-valve TAVR, prompting evaluation of the impact of implanted valve type and balloon post-dilation on echocardiographic outcomes and mortality.
Does the use of self-expandable valves with balloon post-dilation improve transprosthetic gradients compared to balloon-expandable or non-post-dilated self-expandable valves in patients undergoing ViV-TAVR?
Does the use of self-expandable valves with balloon post-dilation improve transprosthetic gradients compared to balloon-expandable or non-post-dilated self-expandable valves in patients undergoing ViV-TAVR?
In patients undergoing ViV-TAVR for failed surgical aortic prostheses, the use of self-expandable valves with balloon post-dilation is associated with significantly lower transprosthetic gradients compared to balloon-expandable valves or self-expandable valves without post-dilation.
May lower gradients with self-expandable valves plus post-dilation in ViV-TAVR; hypothesis-generating, should not yet change practice.
Aims Valve-in-Valve transcatheter aortic valve replacement (ViV-TAVR) is an appealing treatment option for patients with degenerated aortic bioprosthetic valves. However, higher post-procedural transprosthetic gradients are more common after ViV-TAVR than after TAVR for native aortic valve stenosis. We sought to evaluate the impact of type of implanted valve and balloon post-dilation on echocardiographic results and mortality in ViV-TAVR patients. Methods and results One hundred and eleven consecutive patients were enrolled. A balloon-expandable valve, a self-expandable valve without balloon post-dilation, and a self-expandable valve with balloon post-dilation were performed in 35 (Group 1), 39 (Group 2), and 37 (Group 3) patients, respectively. All patients underwent comprehensive transthoracic echocardiography at baseline, discharge, and 6–12 months follow-up. Successful ViV-TAVR was performed in 110 patients (99%). Baseline transprosthetic gradients, left ventricular volumes, ejection fraction, and pulmonary artery systolic pressure were similar among groups. All groups experienced a significant reduction in post-procedural gradients at discharge and during the 6–12 months follow-up compared with baseline. At discharge, the lowest mean gradient was observed in Group 3 (12 ± 7 mmHg) compared with both Group 1 (20 ± 9 mmHg) and Group 2 (17 ± 8 mmHg, P = 0.001). This result was confirmed at 6–12 months follow-up (P = 0.012). Similar 5-year all-cause mortality was observed among groups (34%, 36%, 14%, respectively, P = 0.056). Conclusion In patients with failed surgical aortic prosthesis, ViV-TAVR is an effective treatment option associated with sustained improved haemodynamics regardless of transcatheter valve type and use of balloon post-dilation. However, self-expandable valves with balloon post-dilation showed lower transprosthetic gradients.
No takes yet. Share an insight, caveat, or question.
Muratori et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: