Why the study?
During orthotopic heart transplant, CIED removal frequently leaves behind lead fragments, but fragment locations, risk factors, CXR detection sensitivity, and associated sequelae remained unclear.
What is the prevalence, detectability by CXR, and risk factors for retained lead fragments in OHT patients with CIEDs?
What is the prevalence, detectability by CXR, and risk factors for retained lead fragments in OHT patients with CIEDs?
Retained lead fragments are common (20.7%) after heart transplant in patients with CIEDs, and standard chest x-rays are often insensitive for their detection compared to CT scans.
Answers are grounded in this paper and cite their sources.
Retained fragments may be underdetected by CXR in OHT patients with CIEDs; leaves open whether targeted CT screening improves outcomes.
Background During orthotopic heart transplant (OHT), removal of cardiac implantable electronic device (CIED) involves traction from device pocket, frequently leaving behind lead fragments. Objective Determine fragment locations, risk factors, chest x-ray (CXR) sensitivity of fragment detection, and risk of fragment-related sequelae. Methods Among consecutive OHT patients with CIEDs (2017–2024) at our institution, prevalence and location of fragments were determined by CXR and computed tomography (CT) scan. Using CT scan as gold standard, sensitivity of CXR and radiology reports for lead fragments was determined. Regression identified factors associated with fragments, bacteremia, and fragment-related sequelae. Results Of 116 patients, 20.7% (n=24) had fragments (79% by CXR, 21% visible on CT scan only), mostly in the innominate vein (75%). CXR sensitivity for fragments was 79%. Only 7/19 (37%) fragments visible by initial post-OHT CXR were reported. Of 20 initial post-OHT CTs, 13 noted fragments (65%). Incremental 5-year lead dwell time (OR 1.9, 95%CI 1.1-3.1, p=0.017), dual-coil ICD (OR 4.4, 95%CI 1.4-13.8, p=0.011), and increasing number of leads (OR 1.9, 95%CI 1.1-3.6, p=0.023) were associated with fragments. Bacteremia occurred in 23% (33% with fragments vs. 21% without; OR 1.9, 95%CI 0.7-5.2, p=0.19). MRI was deferred in 21% (n=5) of patients with fragments. Neither DVT nor fragment embolization occurred. Conclusion At least 20% of OHT patients have retained lead fragments, usually in the innominate vein. CXR is insensitive in identifying fragments. Bacteremia is common after OHT, and longer lead dwell time, dual-coil defibrillator leads, and increasing number of leads were associated with fragment retention.
No takes yet. Share an insight, caveat, or question.
Bichard et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: