Key result
Colored microspheres correlate strongly with radioactive microspheres for myocardial blood flow despite ~39% overestimation at high flows.
Answers are grounded in this paper and cite their sources.
Demonstrates strong correlation between colored and radioactive microspheres for measuring myocardial blood flow in dogs, indicating colored beads overestimate flow at higher rates.
Measurement of regional myocardial blood flow (RMBF) is crucial in experimental studies of myocardial ischemia and reperfusion in dogs. The standard measurement technique uses radioactive microspheres; however, not all institutions are able to dispose of radioactive waste and therefore cannot make use of this method. We tested a new, nonradioactive microsphere, labeled with colors instead of nuclides. Simultaneous blood flow measurements with two nuclide-labeled and two colored microspheres were performed after coronary occlusion in dogs. Both techniques show a within-method correlation of r greater than 0.98. Duplicate variability for paired RMBF values in 80 samples was 8.7 +/- 0.1% when computed with radioactive microspheres and 13.2 +/- 1.8% when computed with colored microspheres. There was a good correlation in the measurement of RMBF between the radioactive- and colored-microsphere methods (r = 0.98). The best-fitting linear regression line was expressed by the formula: Colored-microsphere RMBF = 1.11 (radioactive-microsphere RMBF)-0.02. When measured by colored microspheres, RMBF was approximately 8% higher than when computed with radioactive microspheres for blood flow values of 0-2 ml/min/g. When blood flow was increased pharmacologically to levels of 2-7.5 ml/min/g, colored microspheres yielded blood flow values 39% higher than the values computed by radioactive microspheres. We conclude that the nonradioactive, colored-microsphere method correlates with the radioactive technique, but at high flows, it yields values greater than those obtained with radioactive microspheres.
No takes yet. Share an insight, caveat, or question.
Hale et al. (1988) studied Experimental myocardial ischemia and coronary occlusion in dogs. Nonradioactive colored microspheres vs. Nuclide-labeled radioactive microspheres was evaluated on Regional myocardial blood flow (RMBF) correlation and duplicate variability (r = 0.98). Nonradioactive colored microspheres correlated strongly with radioactive microspheres for measuring regional myocardial blood flow, though yielding 39% higher values at high flows.
Synapse has enriched 10 related papers. Consider them for comparative context: