Why the study?
Parameters assessing right ventricular systolic function are used daily assuming interchangeability, but whether RV-LSF measured by TTE and TEE are interchangeable perioperatively was undetermined.
Are right ventricular longitudinal shortening fraction measurements by transthoracic and transoesophageal echocardiography interchangeable in patients undergoing cardiac surgery?
Are right ventricular longitudinal shortening fraction measurements by transthoracic and transoesophageal echocardiography interchangeable in patients undergoing cardiac surgery?
Answers are grounded in this paper and cite their sources.
Right ventricular longitudinal shortening fraction measurements obtained via TTE and TEE are highly correlated and clinically interchangeable in the perioperative setting for cardiac surgery patients.
Background Conventional transthoracic (TTE) and transoesophageal echocardiography (TEE) parameters assessing right ventricle (RV) systolic function are daily used assuming their clinical interchangeability. RV longitudinal shortening fraction (RV-LSF) is a two-dimensional speckle tracking parameter used to assess RV systolic function. RV-LSF is based on tricuspid annular displacement analysis and could be measured with TTE or TEE. Objective The aim of the study was to determine if RV-LSF TTE and RV-LSF TEE measurements were interchangeable in the perioperative setting. Methods Prospective perioperative TTE and TEE echocardiography were performed under general anesthesia during scheduled cardiac surgery in 90 patients. RV-LSF was measured by semi-automatic software. Comparisons were performed using Pearson correlation and Bland-Altman plots. RV-LSF clinical agreement was determined as a range of −5 to 5%. Results Of the 114 patients who met the inclusion criteria, 90 were included. The mean preoperative RV-LSF TTE was 20.4 ± 4.3 and 21.1 ± 4.1% for RV-LSF TEE. The agreement between RV-LSF measurements was excellent, with a bias at −0.61 and limits of agreement of −4.18 to 2.97 %. All measurements fell within the determined clinical agreement interval in the Bland-Altman plot. Linear regression analysis showed a high correlation between RV-LSF TTE and RV-LSF TEE measurement (r = 0.9; confidence interval [CI] 95%: [0.87–0.94], p < 0.001). Conclusion RV-LSF TTE and RV-LSF TEE measurements are interchangeable, allowing RV-LSF to be a helpful parameter for assessing perioperative changes in RV systolic function. NCT NCT05404737. https://www.clinicaltrials.gov/ct2/show/NCT05404737 .
No takes yet. Share an insight, caveat, or question.
Beyls et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: