Why the study?
Is epicardial catheter ablation feasible for ventricular tachycardia in patients with mechanical aortic and mitral valves?
Is epicardial catheter ablation feasible for ventricular tachycardia in patients with mechanical aortic and mitral valves?
Epicardial catheter ablation is a potentially useful and feasible therapy for ventricular tachycardia in patients with mechanical aortic and mitral valves where left ventricular access is limited.
Should not yet change practice; hypothesis-generating for epicardial ablation in mechanical valve patients.
BACKGROUND: In patients with mechanical aortic and mitral valves and left ventricular tachycardia, catheter ablation may be prevented by limited access to the left ventricle. METHODS AND RESULTS: In our series of 6 patients, 2 patients underwent direct surgical ablation and 4 underwent epicardial catheter ablation via a pericardial window. All patients had abnormal low voltage areas with fractionated or delayed isolated potentials on the apical epicardium. Most of the ventricular tachycardias were targeted by pace mapping. Sites with a good pace match or abnormal electrograms were ablated using an irrigated radiofrequency ablation catheter. A microscopic pathological evaluation of the resected tissue from 2 of the open-heart ablation patients revealed dense fibrosis on the epicardium compared with the endocardium, supporting the feasibility of an epicardial ablation for the ventricular tachycardia. CONCLUSIONS: Epicardial catheter ablation of ventricular tachycardia is a potentially useful therapy in patients who have mechanical aortic and mitral valves.
No takes yet. Share an insight, caveat, or question.
Soejima et al. (2015) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: