This study presents an experimental and analytical investigation of acoustic insulation in fully submerged water–structure–water configurations, focusing on composite panels under controlled normal-incidence conditions. Fibreglass and carbon fibre reinforced panels were tested in a hydroacoustic facility over 10–300 kHz. Because the reliable bandwidth is limited by the transducers (transmitting hydrophone ≤140 kHz, receiving hydrophone ≤170 kHz), results above approximately 140–150 kHz are reported as indicative only. The apparent insertion loss was obtained from processed acoustic signals using filtering, time-windowing, and RMS-based pressure estimation. Experimental results were compared with classical single-layer and transfer-matrix predictions. For the fibreglass panel, the measured apparent insertion loss remained relatively constant at approximately 7 ± 2 dB, while the models underestimated the measurements by about 5 dB. The carbon fibre panel showed a pronounced peak of approximately 15 dB around 22 kHz and a strong frequency-dependent response not captured by the models. These discrepancies indicate that simplified homogeneous models do not fully represent submerged composite panels. The dataset provides benchmark experimental evidence for validating improved underwater acoustic models.