Why the study?
Fluoroscopy exposure during catheter ablation poses health hazards to patients and operators, prompting evaluation of a low-fluoroscopy workflow using modern contact force technologies in paroxysmal atrial fibrillation ablation.
Does a low-fluoroscopy workflow using contact force technologies reduce fluoroscopy time while maintaining efficacy in patients undergoing paroxysmal atrial fibrillation ablation?
Does a low-fluoroscopy workflow using contact force technologies reduce fluoroscopy time while maintaining efficacy in patients undergoing paroxysmal atrial fibrillation ablation?
A low-fluoroscopy workflow using contact force and intracardiac echocardiography for PAF ablation is feasible, safe, and effective, with a rapid learning curve.
Supports low-fluoroscopy PAF ablation feasibility; hypothesis-generating and requires prospective validation before broader adoption.
BACKGROUND: Fluoroscopy exposure during catheter ablation is a health hazard to patients and operators. This study presents the results of implementing a low-fluoroscopy workflow using modern contact force (CF) technologies in paroxysmal atrial fibrillation (PAF) ablation. METHODS: Catheter (ST) was advanced into the right atrium. The decapolar catheter was placed without fluoroscopy. A double-transseptal puncture was performed under intracardiac echocardiography guidance. ST and mapping catheters were advanced into the left atrium. A left atrial map was created, and pulmonary vein (PV) isolation was confirmed via entrance and exit block before and after the administration of isoproterenol or adenosine. RESULTS: Forty-three patients underwent PAF ablation with fluoroscopy reduction workflow (mean age: 66±9 years; 70% male), performed by five operators. Acute success rate (PV isolation) was 96.5% of PVs. One case of pericardial effusion, not requiring intervention, was the only acute complication. Mean procedure time was 217±42 minutes. Mean fluoroscopy time was 2.3±3.0 minutes, with 97.7% of patients having < 10 minutes and 86.0% having < 5 minutes. A significant downward trend over time was observed, suggesting a rapid learning curve for fluoroscopy reduction. Freedom from any atrial arrhythmias without reablation was 80.0% after a mean follow-up of 12±3 months. CONCLUSION: Low fluoroscopy time is achievable with CF technologies after a short learning curve, without compromising patient safety or effectiveness.
No takes yet. Share an insight, caveat, or question.
Zei et al. (2019) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: