Why the study?
Does a single 24-hour levosimendan infusion improve haemodynamics in patients with advanced but stable chronic heart failure?
Does a single 24-hour levosimendan infusion improve haemodynamics in patients with advanced but stable chronic heart failure?
A single 24-hour infusion of levosimendan improves haemodynamics and reduces NT-proBNP in patients with advanced but stable chronic heart failure.
Answers are grounded in this paper and cite their sources.
May support short-term levosimendan in stable advanced HF; leaves open confirmation in RCTs.
AIMS: Levosimendan improves haemodynamics in acute decompensated heart failure (HF). However, it is increasingly used for repetitive or intermittent infusions in advanced but stable chronic HF, without clear indication, selection criteria, or effect. We tested the hypotheses that (1) levosimendan improves haemodynamics in stable chronic HF and (2) that the response is dependent on baseline clinical and haemodynamic factors. METHODS AND RESULTS: Twenty-three patients [median age 56 (49-64) years, four (17%) women] with stable New York Heart Association (NYHA) III and IV HF received a single 24 h levosimendan infusion. Non-invasive haemodynamics (inert gas re-breathing technique), estimated glomerular filtration rate, and N-terminal pro-brain natriuretic peptide were assessed before and after infusion. Levosimendan had the following effects (median change): a significant increase in cardiac output (+9.8 ± 21.6%; P = 0.026) and decrease in N-terminal pro-brain natriuretic peptide (-28.1 ± 16.3%, P < 0.001), estimated total peripheral resistance (-16.9 ± 18.3%, P = 0.005), and mean arterial pressure (-5.9 ± 8.2%, P = 0.007), but no change in estimated glomerular filtration rate (+0.89 ± 14.0%, P = 0.955). There were no significant associations between baseline clinical and/or haemodynamic factors and the levosimendan effect on cardiac output. CONCLUSIONS: Levosimendan was associated with improved haemodynamics in patients with stable chronic HF, but we could not identify any predictors of the magnitude of haemodynamic response.
No takes yet. Share an insight, caveat, or question.
Najjar et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: