The study was conducted to examine the prevalence and incidence of externalized conductors and electrical dysfunction in patients with selected St. Jude Medical defibrillator and left ventricular leads.
What is the prevalence of externalized conductors and electrical dysfunction in different models of St. Jude Medical defibrillator and left ventricular leads?
What is the prevalence of externalized conductors and electrical dysfunction in different models of St. Jude Medical defibrillator and left ventricular leads?
Durata leads demonstrated a 98% reduction in the prevalence of externalized conductors compared to Riata/Riata ST leads, confirming significantly improved abrasion resistance and durability.
Answers are grounded in this paper and cite their sources.
Durata leads may reduce externalized conductor risk versus Riata models; supports design improvements but leaves open need for prospective validation.
Background: The Cardiac Lead Assessment Study (CLAS) was a large prospective, multicenter, international postmarket surveillance study conducted at 45 sites. Objective: The purpose of CLAS was to examine the prevalence and incidence of externalized conductors and electrical dysfunction in subjects with selected St. Jude Medical defibrillator and left ventricular leads. Methods: Cinefluoroscopy was used to determine the presence of externalized conductors at enrollment and at 12-, 24-, and 36-month follow-up visits. Lead electrical measurements were collected systematically. Results: The study enrolled 2216 subjects with a total of 2847 study leads. The prevalence of externalized conductors through 36 months for Riata leads was 30.9%, Riata ST leads 12.6%, Durata leads 0.5%, and QuickSite/QuickFlex leads 4.7%. The prevalence of electrical dysfunction through 36 months for Riata was 4.0%, Riata ST 3.3%, Durata 2.4%, and QuickSite/QuickFlex 0.3%. In Riata and Riata ST leads with externalized conductors, there was a low risk of electrical dysfunction. None of the Durata or QuickSite/QuickFlex leads with externalized conductors developed electrical dysfunction. There was no evidence of an electrical short in a high-voltage shocking circuit leading to failed shock. Conclusion: A high prevalence of externalized conductors was found in Riata and Riata ST defibrillator leads, with a higher risk of externalization for 8F Riata leads than for 7F Riata ST leads. The 98% reduction in prevalence of externalized conductors in Durata leads compared to Riata/Riata ST leads confirms that the design improvements culminating in Durata leads significantly improved abrasion resistance and durability.