Key result
Subcutaneous ICD linked to ~70% fewer procedural and lead complications versus transvenous ICD.
Why the study?
Although S-ICD is non-inferior to TV-ICD regarding device complications and inappropriate shocks, its long-term clinical outcomes compared with TV-ICD in Japanese patients needed evaluation.
Does subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation with a SMART Pass filter provide comparable long-term efficacy and superior safety regarding procedure- and lead-related complications compared with transvenous ICD (TV-ICD) in propensity score-matched Japanese patients?
Cohort (n=315)
No
Does subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation with a SMART Pass filter provide comparable long-term efficacy and superior safety regarding procedure- and lead-related complications compared with transvenous ICD (TV-ICD) in propensity score-matched Japanese patients?
Answers are grounded in this paper and cite their sources.
In propensity score-matched Japanese patients, S-ICD with the SMART Pass filter demonstrated comparable long-term mortality, appropriate shocks, and inappropriate shocks to TV-ICD, while significantly reducing procedure- and lead-related complications.
Background Subcutaneous implantable cardioverter‐defibrillator (S‐ICD) has been reported to be non‐inferior to transvenous ICD (TV‐ICD) in terms of device‐related complications and inappropriate shock (IAS). We aimed to evaluate the long‐term clinical outcomes of S‐ICD compared with TV‐ICD in Japanese patients. Methods We studied 315 consecutive patients (TV‐ICD, 167; S‐ICD, 148) who underwent ICD implantation. A propensity score matching analysis was performed to select patient subgroups for comparison (104 patients in each group). Clinical outcomes, including appropriate and inappropriate ICD therapy, procedure‐ and lead‐related complications, and mortality, were compared between the two groups. Results During follow‐up (median, 1458 [interquartile range, 1353–1572] days), the cumulative incidence of appropriate shock therapy was 9.6% and 8.7% in the S‐ICD and TV‐ICD groups, respectively ( p = 0.94). Although the S‐ICD group tended to have a higher IAS than the TV‐ICD group (5.8% vs. 1.9%), the difference was not significant ( p = 0.19). Conversely, the cumulative incidence of procedural and lead‐related complications was significantly lower in the S‐ICD group (2.9% vs. 9.6%, p = 0.02). Notably, lead‐related complications were more common in the TV‐ICD group ( p = 0.05). There was no difference in all‐cause mortality between the two groups ( p = 0.75), and heart failure exacerbation was the most common cause of death in both groups. Conclusions In propensity score‐matched Japanese patients with S‐ICD, the cumulative incidence of appropriate shock and mortality was comparable to those with TV‐ICD. There was no significant difference in the rate of IAS. Notably, patients with S‐ICD had fewer lead‐related complications than those with TV‐ICD.
No takes yet. Share an insight, caveat, or question.
Konno et al. (2025) conducted a cohort in Indication for implantable cardioverter-defibrillator (ICD) implantation for primary or secondary prevention of sudden cardiac death (n=315). Subcutaneous implantable cardioverter-defibrillator (S-ICD) with SMART Pass filter vs. Transvenous implantable cardioverter-defibrillator (TV-ICD) was evaluated on Cumulative incidence of procedural and lead-related complications (p=0.02). Subcutaneous ICD was associated with fewer procedural and lead-related complications and comparable appropriate shocks compared to transvenous ICD.
Synapse has enriched 10 related papers. Consider them for comparative context: