Why the study?
Does M-mode echocardiography reliably screen for systemic hypertension in cats?
Does M-mode echocardiography reliably screen for systemic hypertension in cats?
M-mode echocardiography is an unreliable screening test for systemic hypertension in cats due to the marked variability of echocardiographic findings.
M-mode echocardiography should not guide hypertension screening in cats; this cohort study leaves open the search for reliable echocardiographic markers.
A retrospective study was performed in 75 hypertensive cats to determine the spectrum and frequency of M-mode echocardiographic abnormalities. Results indicated that 21.3% of the cats had M-mode measurements within normal reference ranges. For cats with echocardiographic abnormalities, changes were variable. Thirty-nine percent of hypertensive cats had hypertrophy of the interventricular septum in diastole, and 41.3% had hypertrophy of the left ventricular (LV) posterior wall in diastole. One cat in five had a dilated left atrium, while fractional shortening and LV internal dimension in diastole were normal in 82.7% and 86.7% of the cats, respectively. The marked variability of echocardiographic findings in hypertensive cats made echocardiography an unreliable screening test for hypertension.