Key result
Repeated squat-stand durations can be reliably shortened from 300 s to 180 s to identify cerebral pressure-flow directional sensitivity (ICC >0.90).
Why the study?
The reliability of the time-corrected ratio metric used to characterize cerebral pressure-flow directional sensitivity had not been evaluated across reduced repeated squat-stand durations.
Can shorter duration repeated squat-stands reliably measure cerebral pressure-flow directional sensitivity compared to a 300 s reference standard in healthy adults?
Observational (n=99)
Can shorter duration repeated squat-stands reliably measure cerebral pressure-flow directional sensitivity compared to a 300 s reference standard in healthy adults?
The magnitude of changes in middle cerebral artery mean blood velocity (MCAv) is attenuated when mean arterial pressure (MAP) increases compared with when MAP decreases. This directional sensitivity has been characterized using a time‐corrected ratio calculated on MCAv and MAP changes induced by repeated squat–stands (RSS) at 0.05 and 0.10 Hz for 300 s (∆MCAv T /∆MAP T ). Herein, we examined the reliability of the metric within reduced RSS durations. Ninety‐nine (25 females) healthy human participants (26 ± 5 years) performed 300 s RSS at 0.05 Hz (20 s cycles) and 0.10 Hz (10 s cycles) while MCAv and MAP were measured continuously. The ∆MCAv T /∆MAP T was calculated for each transition [increase (INC); decrease (DEC)] of MAP for 60, 120, 180, 240 and 300 s. A two‐way ANOVA was completed, and the absolute (Bland–Altman plot) and relative (coefficient of variation and intraclass correlation coefficient) reliability were calculated to compare shorter‐duration recordings with 300 s (reference standard). At 0.05 Hz, ∆MCAv T /∆MAP T was similar between INC and DEC and comparable to the 300 s reference from 120 s onwards. At 0.10 Hz, ∆MCAv T /∆MAP T was lower during INC ( p < 0.0001). Bland–Altman plots indicated that differences trended towards zero (greater agreement) with increasing duration. Averaged coefficients of variation were <10% from 120 s (0.05 Hz) and 60 s (0.10 Hz) onwards. All intraclass correlation coefficients were >0.90 for recordings of ≥180 s in both frequencies. Although the 300 s reference is optimal, RSS duration could be shortened to 180 s, if needed, to identify this hysteresis‐like pattern reliably using ∆MCAv T /∆MAP T .
No takes yet. Share an insight, caveat, or question.
Labrecque et al. (2025) conducted an observational in Healthy (n=99). Shorter repeated squat-stand (RSS) durations (60-240 s) vs. 300 s RSS duration was evaluated on Reliability of ∆MCAv T /∆MAP T (intraclass correlation coefficient) (ICC >0.90). Repeated squat-stand durations can be reliably shortened from 300 s to 180 s to identify cerebral pressure-flow directional sensitivity (ICC >0.90).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: