Why the study?
Characteristic PET/CTA patterns of FDG uptake and anatomic changes after prosthetic heart valve implantation over time needed definition to prevent misdiagnosing post-operative inflammation and avoid false positives.
What are the characteristic [18F]FDG PET/CTA patterns of FDG uptake and anatomic changes following prosthetic heart valve implantation over time in patients without suspected infection?
What are the characteristic [18F]FDG PET/CTA patterns of FDG uptake and anatomic changes following prosthetic heart valve implantation over time in patients without suspected infection?
FDG uptake in recently implanted prosthetic valves shows a stable, characteristic pattern of post-operative inflammation for at least 1 year, suggesting it can be a normal finding in the absence of anatomic lesions.
AIMS: To define characteristic PET/CTA patterns of FDG uptake and anatomic changes following prosthetic heart valves (PVs) implantation over time, to help not to misdiagnose post-operative inflammation and avoid false-positive cases. METHODS AND RESULTS: Prospective evaluation of 37 post-operative patients without suspected infection that underwent serial cardiac PET/CTA examinations at 1, 6, and 12 months after surgery, in which metabolic features (FDG uptake distribution pattern and intensity) and anatomic changes were evaluated. Standardized uptake values (SUVs) were obtained and a new measure, the valve uptake index (VUI), (SUVmax-SUVmean)/SUVmax, was tested to homogenize SUV results.In total, 111 PET/CTA scans were performed in 37 patients (19 aortic and 18 mitral valves). FDG uptake was visually detectable in 79.3% of patients and showed a diffuse, homogeneous distribution pattern in 93%. Quantitative analysis yielded a mean maximum standardized uptake value (SUVmax) of 4.46 ± 1.50 and VUI of 0.35 ± 0.10. There were no significant differences in FDG distribution or uptake values between 1, 6, or 12 months. No abnormal anatomic changes or endocarditis lesions were detected in any patient during follow-up. CONCLUSIONS: FDG uptake, often seen in recently implanted PVs, shows a characteristic pattern of post-operative inflammation and, in the absence of associated anatomic lesions, could be considered a normal finding. These features remain stable for at least 1 year after surgery, so questioning the recommended 3-month safety period. A new measure, the VUI, can be useful for evaluating the FDG distribution pattern.
No takes yet. Share an insight, caveat, or question.
Roque et al. (2019) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: