Why the study?
Are increased plasma MCP-1 antigen levels associated with an increased risk of restenosis after coronary stent implantation in patients with stable exertional angina?
Are increased plasma MCP-1 antigen levels associated with an increased risk of restenosis after coronary stent implantation in patients with stable exertional angina?
Elevated relative plasma MCP-1 levels at 48 hours and 6 months post-stenting are associated with an increased risk of angiographic restenosis in patients with stable exertional angina.
Answers are grounded in this paper and cite their sources.
MCP-1 rises post-stenting were associated with restenosis; hypothesis-generating and requires prospective validation before clinical adoption.
Monocyte chemoattractant protein-1 (MCP-1) plays a fundamental role in monocyte recruitment and has been implicated in atherosclerosis. The present study tested the hypothesis that increased levels of MCP-1 are associated with an increased risk for restenosis post stent implantation. The plasma MCP-1 antigen levels were measured pre-stenting, and at 24 and 48 h and 6 months post stenting in 41 patients with stable exertional angina (SEA) who had undergone successful stent implantation. Nineteen patients with chest pain syndrome were selected as a control group. Initial plasma MCP-1 antigen levels (mean +/- SE, pg/ml) in the patients with SEA were significantly higher than those in the control group (852.3+/-51.4 vs 418.2+/-26.7, p<0.001). The patients with SEA were divided into 2 groups based on follow-up angiographic findings: 17 patients with restenosis (R group); 24 patients without restenosis (N group). The lesion was significantly longer in the R group than in the N group (p<0.03). Plasma MCP-1 antigen levels at pre-stenting were not significantly different between the 2 groups (820.6+/-69.1 in the R group vs 874.7+/-73.8 in the N group). Serial changes of plasma MCP-1 levels were plotted as percent changes from the initial levels (mean +/- SE, %) and were significantly higher in the R group than in the N group at 48 h and at 6 months post stent implantation (104.6+/-4.8 vs 89.2+/-3.4, p<0.01, 109.6+/-11.2 vs 98.5+/-5.0, p<0.05). The study concludes that MCP-1 production at stented coronary arterial sites is associated with an increased risk for restenosis post stent implantation.
No takes yet. Share an insight, caveat, or question.
Oshima et al. (2001) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: