Why the study?
Management of peri-device leak after left atrial appendage closure remains controversial, and procedural features and clinical outcomes of leak closure have not been well established.
Does percutaneous closure of peri-device leak following LAA closure result in successful closure and safe clinical outcomes?
Does percutaneous closure of peri-device leak following LAA closure result in successful closure and safe clinical outcomes?
Percutaneous closure of peri-device leaks following LAA closure using coils, plugs, or second occluders is safe, feasible, and associated with favorable clinical outcomes.
Answers are grounded in this paper and cite their sources.
Supports percutaneous PDL closure after LAA occlusion; confirms safety and feasibility in systematic synthesis of current evidence.
OBJECTIVE: This study aimed to examine the cumulative experience of peri-device leak (PDL) closure following left atrial appendage (LAA) closure. BACKGROUND: The management of PDL following LAA closure remains controversial. While PDL closure has been proposed, procedural features and clinical outcomes have not been well established. METHODS: A systematic review of all published cases of PDL closure with available anatomical, procedural, and clinical outcomes was performed. RESULTS: We identified 18 indexed publications and 110 cases between April 2013 and March 2020. 71 patients (mean age 72 ± 8 yrs), met study criteria and were included. PDL closure was most common in males, bilobar LAA morphology, and after Watchman procedures. The mean PDL size was 7.6 ± 5.8 mm (range 2-26 mm). Leaks were classified according to size: small (<5 mm; 45%), moderate (≥5-9 mm; 25%), and large (≥10 mm; 30%). Endovascular coils and endovascular plugs were used to close both small and moderate sized leaks, and second LAA closure devices were exclusively used for large PDLs. Successful PDL closure occurred in 90%, and was similar between PDL sizes and types of occluder used. Procedural complication rates were uncommon (2.8%). No strokes were reported following PDL closure at 6 months. CONCLUSIONS: In patients with PDL for whom discontinuation of OAC may be considered unsafe, percutaneous closure using a tailored approach with either endovascular coils, plugs, or second occluder represents a safe, and feasible alternative associated with favorable clinical outcomes.
No takes yet. Share an insight, caveat, or question.
Sleiman et al. (2021) studied this question.