Answers are grounded in this paper and cite their sources.
The MediGuide System offers a novel approach to integrate 3D electromagnetic mapping with fluoroscopy, potentially enhancing safety and efficacy in complex VT ablations by reducing radiation exposure.
Ventricular tachycardia in patients with structural heart disease is a clinical relevant arrhythmogenic disorder. Many of these patients require a combination of implantable cardioverter-defibrillator (ICD) for prevention of sudden cardiac death with antiarrhythmic medications to decrease the frequency of ventricular tachycardia (VT) episodes. However, ICD cannot prevent arrhythmia episodes and medication has only limited efficacy and in relevant number of patients it has to be discontinued due to multiple side effects. Several reports in the last decade have shown that in patients with frequently recurrent ventricular arrhythmia episodes catheter ablation can be a highly effective therapy as an adjunct to ICD and/or medical treatment. In addition, the SMASH-VT and VTACH trials demonstrates, that prophylactic VT ablation results in a prolonged time to recurrence of VT in patients with stable VT, previous myocardial infarction, and reduced left ventricular ejection fraction.1,2 According to this data it is hardly surprising that, besides atrial fibrillation ablation, treatment of ventricular tachycardia is the next big frontier in the field of interventional therapy of cardiac arrhythmias. However, management of ventricular tachycardia is still challenging driven by a complex three-dimensional substrate. Successful treatment requires a comprehensive understanding and visualization of cardiac anatomy and electrical activation. Beside conventional fluoroscopy, 3-D electromagnetic mapping systems have been introduced to facilitate catheter navigation. Currently used techniques have some weaknesses. For instance, fluoroscopy provides only two-dimensional information, where it is difficult to repeatedly guide the catheter to the same area of interest. Thus, with prolonged procedures there is an increased X-ray exposure, adding risk for both the patient and the physician. One limitation of available 3-D-mapping system is failing to sufficiently compensate for respiratory, cardiac cycle, and patient movement and the limited integration on fluoroscopy. Recently, a new intracardiac navigation system (MediGuide™ System) was introduced to overcome this limitation and to merge the key benefits of fluoroscopy and 3-D-mapping system in a unique manner. In the following we are going to introduce this technology and present potential implications on interventional treatment of ventricular arrhythmias. The MediGuide-System consists of three components1: a miniaturized single coil sensor (<1 mm3) assembled within an intracardiac device such as a conventional EP catheter2; an electromagnetic field reference sensor attached to the patient's chest, and3 a transmitter generating a 3-D electromagnetic field. The transmitter is mounted on the fluoroscopy detector of a conventional X-ray system aligning the fluoroscopy space with the 3-D magnetic sensor field. As a result, the sensor equipped EP catheter can be tracked real-time, non-fluoroscopically by the electromagnetic sensor field in pre-recorded fluoroscopy cine loops and visualized within the X-ray environment. Within this cineloops points/region of interest can be marked and visualized with landmark icons, which will be adapted to the 3-D-electromagnetic field. To adjust for cardiac cycle-dependent changes in catheter position the speed of the cine loop is matched to the real-time ECG signal. The magnetic field reference sensor allows the MediGuide-System to accurately display the intracardiac catheter position and to compensate for respiration and patient movement.3,4 In addition, all this information (e.g. position in the 3-D-electromagnetic sensor field) can be implemented in a 3-D-electroanatomic mapping system and contributes to geometry creation and can be used as a stable positional reference. Ablation of ventricular tachycardia is one of the most challenging ablation procedures in the field of cardiac electrophysiology. Procedures are often associated with significant procedure duration and significant radiation exposure for both, patient and physician. Stevenson and colleagues5 report for instance in a large multicenter series a median procedure duration of 315 min (254–395) with fluoroscopy time of 45 (30–71) min. By visualization of the EP-catheter within dynamic pre-recorded cineloops, the MediGuide-Technology can contribute to decreasing the fluoroscopy times. In addition, by acquisition of these cine-loops as a ventriculography, specific finding for example aneurysms of the ventricle or location of the papillary muscles as a substrate for ventricular arrhythmia can be visualized and displayed continuously and used as background for catheter navigation and mapping (Figure 1). Nonfluoroscopic endocardial mapping of the left ventricle via transseptal approach. After the positioning of MediGuide-Sensor enabled EP-Catheter in the coronary sinus and the apex of the right ventricle cine loops were acquired as a ventriculography in an RAO and LAO projection. The MediGuide-Sensor-enabled catheters are tracked real-time, non-fluoroscopically by the electromagnetic sensor field and projected as an icon on their inctracardiac position within this prerecorded cine-loops. The icon projection and the cine loops are fully compensated for respiratory, cardiac cycle, and patient movement. Yellow icon indicates the tip of the coronary sinus catheter, the red icon the catheter at the apex of the right ventricle and the green icon the mapping catheter in the left ventricle. CS, coronary sinus; RVA, right ventricular apex, MAP, mapping catheter, RV-Lead, defibrillator lead in the right ventricle, TSP-S, transseptal sheath, RAO,right anterior oblique, LAO, left anterior oblique. The real-time non-fluoroscopy cineloops could be an auxiliary tool at the challenging scenario of epicardial VT ablation especially at patients with dilatative cardiomyopathy. In such circumstances the anatomical proximity of the coronary arteries to the origin of arrhythmia can be an obstacle for successful and safe ablation.6 Therefore, a peri-interventional coronary angiography is mandatory. Performance of this angiography as an underlying cine-loop for the MediGuide-System enables a continuous visualization of the coronaries during catheter movement and ablation energy delivery and can support the operator to avoid complications. Activation mapping of tachycardia supported by 3-D electro anatomic mapping system allows significant information for successful treatment. However, current available 3-D electro anatomic mapping systems are partially restricted for cardiac cycle compensation and may lead to only limited accurate catheter visualization and map acquisition. By matching the cine loops and sensor movement to real-time ECG signal, the MediGuide-Systems allows a real-time tracing of the sensor equipped catheters. As mentioned before, the transmitter of the 3-D electromagnetic field of the MediGuide-System is mounted on the fluoroscopy detector. This means that the field stability and accuracy is autarkical from patient movement. Furthermore, an electromagnetic field reference sensor attached on the chest detects respiratory movement of the patient and can employ this information for online adaptation of catheter visualization and image alignment. Implementation of all this information can facilitate the accuracy and stability of 3-D electro anatomic mapping systems. Further developments of this GPS-guided location system may lead to safe and effective ablation procedures with no or minimum fluoroscopy even in such complex arrhythmias-like ventricular tachycardia. Conflict of interest: T.G., S.K., A.A., P.S., S.R., G.H., and C.P., have received modest lecture honoraria and congress sponsoring from St. Jude Medical and Biotronik.
No takes yet. Share an insight, caveat, or question.
Gaspar et al. (2012) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: