Why the study?
Can median intradialytic blood pressure track changes in interdialytic ambulatory blood pressure evoked by probing dry-weight in hypertensive hemodialysis patients?
Can median intradialytic blood pressure track changes in interdialytic ambulatory blood pressure evoked by probing dry-weight in hypertensive hemodialysis patients?
Median intradialytic BP can track population-level changes in ambulatory BP during dry-weight reduction, but wide limits of agreement limit its utility for individual patient prediction.
Supports median intradialytic BP for population-level ambulatory BP tracking during dry-weight reduction; leaves open individual-level reliability in hemodialysis.
BACKGROUND: Median BP obtained over a single dialysis treatment can diagnose hypertension among hemodialysis patients. Whether median BP is as useful to track change in BP is unknown. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Among patients participating in the dry-weight reduction in hypertensive hemodialysis patients (DRIP) trial, interdialytic ambulatory BP was recorded at baseline, 4 weeks, and 8 weeks. The mean interdialytic ambulatory BP was compared to the following recordings: predialysis on one dialysis treatment (Pre1), predialysis averaged over 2 weeks of dialysis treatment (Pre6), postdialysis on one dialysis treatment (Post1), postdialysis averaged over 2 weeks of dialysis treatment (Post6), and median intradialytic BP over one treatment. RESULTS: Pre1 was unable to detect change in ambulatory BP. Although Pre6 was able to detect change, it overestimated the ambulatory BP. On average, the magnitude of reduction in Post1 in response to probing dry-weight was nearly twice that obtained by ambulatory BP monitoring. Even Post6 overestimated the magnitude of reduction in BP at 8 weeks. Median systolic BP was responsive to probing dry-weight and neither overestimated nor underestimated the interdialytic ambulatory systolic BP at baseline or over time. However, the SD of the differences between median systolic BP and interdialytic ambulatory systolic BP varied from 16 to 20 mmHg. CONCLUSIONS: Median intradialytic BP recordings can detect change in ambulatory BP evoked by reduction in dry-weight at the population level. Because of wide agreement limits between intradialytic and interdialytic BP, the individual prediction of ambulatory BP from median intradialytic BP can be misleading.
No takes yet. Share an insight, caveat, or question.
Agarwal et al. (2010) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: