Answers are grounded in this paper and cite their sources.
This paper reports on a comparison between a commercially available quantum-well infrared focal plane array (FPA) and a custom quantum-dot (QD)-in-a-well (DWELL) infrared FPA in the long-wave infrared (LWIR). The DWELL detectors consist of an active region composed of InAs QDs embedded inIn.15Ga.85Asquantum wells. DWELL samples were grown using molecular beam epitaxy and fabricated into 320×256 pixels FPA with a flip-chip indium bump technique. Both the DWELL and QmagiQ commercial quantum-well detector were hybridized to an Indigo ISC9705 readout circuit and tested in the same camera system. Calibrated blackbody measurements at a device temperature of 60 K with LWIR optics yield a noise equivalent change in temperature of 17 mK and 91 mK for quantum-well and DWELL FPAs operating at 0.95- and 0.58-V biases, respectively. The comparison of the DWELL and quantum-well FPA when imaging a 35∘Cblack body showed that the DWELL had a signal-to-noise ratio of 124 while the quantum-well FPA showed 1961. As well, the quantum-well FPA showed a higher collection efficiency of 1.3 compared to the DWELL.
No takes yet. Share an insight, caveat, or question.
Andrews et al. (2009) studied this question.