Why the study?
Are continuous wave Doppler indices of aortic flow sensitive to changes in global cardiac function during controlled myocardial ischemia induced by coronary angioplasty?
Are continuous wave Doppler indices of aortic flow sensitive to changes in global cardiac function during controlled myocardial ischemia induced by coronary angioplasty?
Doppler indices of aortic flow, particularly V2/T and MD, are highly sensitive to transient global left ventricular dysfunction induced by ischemia during coronary angioplasty.
Answers are grounded in this paper and cite their sources.
May support Doppler indices for detecting transient LV dysfunction; leaves open their added value in routine clinical monitoring.
OBJECTIVE: To assess the sensitivities of Doppler indices to changes in global cardiac function during and after controlled myocardial ischaemia induced by coronary angioplasty. DESIGN: Continuous wave Doppler signals of aortic flow were recorded during coronary angioplasty. The following Doppler indices of cardiac function were measured before, during, and after balloon inflation: V (peak velocity), MA (mean acceleration), V2/T (T = time from onset to peak ejection), and MD (minute distance corrected for baseline heart rate). SETTING: A tertiary care cardiological unit in a university hospital. PATIENTS: Sixteen patients undergoing coronary angioplasty of the left anterior descending coronary artery. Eight patients had multivessel disease. MAIN OUTCOME MEASURES: The primary outcome measures were planned before data collection began. RESULTS: 12 patients showed a significant fall of three or more Doppler indices from their baseline values during balloon inflation. This occurred in all patients with multivessel disease. The Doppler indices V2 T, MD, V, and MA fell by 43.7%, 37.7%, 27.4%, and 23% respectively from their baseline values (p less than 0.0001). The relative sensitivities of the Doppler indices to ischaemia were V2/T greater than MD (p less than 0.02), MD greater than (p less than 0.001), and V greater than MA (p less than 0.01). The impairment of global left ventricular function resulting from brief balloon inflation during single vessel angioplasty was reversible in all the patients. CONCLUSIONS: The Doppler indices V2/T, MD, V, and MA are all sensitive, in order of magnitude, to falls in global cardiac function resulting from ischaemia. They may prove useful for assessing cardiac function during ischaemia in the clinical setting.
No takes yet. Share an insight, caveat, or question.
Hunt et al. (1991) studied this question.