Answers are grounded in this paper and cite their sources.
Workload simulation is a core procedure of spindle reliability tests. On spindle-force working-condition simulation platforms that are based on electro-hydraulic servo systems (EHSSs), accurate force-tracking control is difficult to achieve because of several factors, such as difficulty in obtaining the EHSS parameters, complex dynamic spindle models, uncertain disturbances during the loading process. A nonlinear fuzzy dynamic matrix control (FDMC) strategy, which considers these factors, was developed during this study. Step responses of the EHSS were collected and a status equation was established in accordance with the dynamic matrix control (DMC) strategy; thus, the problems associated with obtaining the parameters were solved. For the unknown disturbances that are caused by other factors, such as gaps in the structure, the effects of the predictive weighting parameter in the DMC strategy on the tracking performance of the system were analyzed by the performance of simulation experiments. In addition, a nonlinear DMC strategy that is based on the transient predictive weighting parameter was proposed, the strict asymptotic stability of the closed-loop system was proven by the application of Lyapunov’s second method, and a stability-range design method for the predictive weighting parameter was developed. Then, a concise SISO fuzzy-parameter tuner was used to obtain the online-forecasting weighting parameter, and the FDMC design was realized. The proposed nonlinear FDMC controller solves the problems associated with the tracking performance and robustness of the control system, that is, the tuning difficulty caused by the invariability of the predictive weighting coefficient in the conventional DMC controller. The asymptotic stability of this nonlinear controller was also proven. Finally, in this study, FDMC was used for a spindle radial force-loading system that was based on an EHSS and physical experiments were performed. Then, the force-tracking performance of this controller was compared with that of a DMC controller, a PI controller, and a controller proposed by other scholars. The experimental results indicated that the FDMC controller had greater robustness than the conventional DMC controller; thus, it satisfies the loading requirements. The proposed FDMC controller also exhibited a better tracking performance and a greater control bandwidth than the other controllers.
No takes yet. Share an insight, caveat, or question.
Zu’an Ding (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: