The postoperative intraocular lens (IOL) chamber depth was predicted using a multiple linear regression analysis of the postoperative chamber depth as a function of the corneal height, the preoperative chamber depth, and the axial length in 279 patients with a posterior chamber lens implant. Based on a linear regression formula incorporating these preoperatively defined parameters, the postoperative IOL chamber depth could be predicted with a correlation coefficient of 0.71 and an error of +/- 0.30 mm (SD). It is concluded that an individual prediction of the IOL chamber depth will improve the accuracy in IOL calculation.
No takes yet. Share an insight, caveat, or question.
Olsen et al. (1990) studied this question.