Answers are grounded in this paper and cite their sources.
The factors which can affect the reliability of probe measurements in afterglows are discussed. It is concluded from measurements made in nitrogen afterglows that the main source of error is the variation of plasma potential with probe current, which falsifies the electron temperature measurements. An electron source (a heated tungsten filament) has been used in the afterglow in an attempt to remove this source of error, and it is concluded that this technique makes the probe measurements reliable. It was also found that the electron source maintained the afterglow electron temperature at a value close to the source temperature. By varying both the source temperature and the total gas pressure, afterglow electron temperatures between 1000°K and 2600°K have been obtained in ammonia-helium gas mixtures.
No takes yet. Share an insight, caveat, or question.
Court et al. (1964) studied this question.