Why the study?
Does delayed-enhancement cardiac magnetic resonance (DE-CMR) improve outcomes and procedural efficiency in patients undergoing re-ablation of atrial fibrillation?
Does delayed-enhancement cardiac magnetic resonance (DE-CMR) improve outcomes and procedural efficiency in patients undergoing re-ablation of atrial fibrillation?
Answers are grounded in this paper and cite their sources.
This authors' reply clarifies that DE-CMR may reduce total procedural time in AF re-ablation by identifying scar gaps a priori, though its effect on specific procedural metrics requires further adequately powered studies.
We appreciate the Hammache et al. interesting insights on our recent paper in Europace.1 They raise a series of interesting concerns and comments that warrant further discussion and clarification.2 We appreciate their timely comments on topics that had only been briefly addressed in our manuscript. Indeed, in a proof-of-concept study, we previously reported on the feasibility and acute efficacy of delayed-enhancement cardiac magnetic resonance (DE-CMR) to re-isolate pulmonary veins.3 Patients in the present study had not been included in the original pivotal study.3 Hammache et al. are also concerned on the type of recurrence after ablation. In our study, a diagnosis of recurrent arrhythmia was reached by mean of 12-lead electrocardiogram (ECG) or 24-h ECG Holter monitoring. Although the seven atrial flutter recurrences were labelled as left atrial flutter by the treating electrophysiologist, the localization of the macro-reentrant circuit was not confirmed in an electrophysiological study. Because potential limitations in ECG interpretation,4 we felt that further subanalyses based on flutter origin may be inaccurate and misleading. The reasons behind a shorter duration of the ablation procedure in the DE-CMR group could not be clarified in our study. Certainly, while we found significant differences in the total procedural time, this was not the case for radiofrequency and fluoroscopy time, for which a clear reduction in the DE-CMR group did not meet statistical significance. Large inter-individual variability likely rendered our study underpowered to detect significant differences in each of these items. Moreover, tasks others than the aforementioned may have contributed to shorten procedures. For example, a priori identification of scar gaps in DE-CMR might reduce time spent in mapping and identifying gaps. Our procedural time was longer than in the CLOSE protocol,5 but both studies are likely not comparable due to procedural differences amongst centres. In many fields of clinical research, also in atrial fibrillation (AF) ablation, advances in medical technology and drugs are tested in parallel and their development and validation usually overlap, in most cases as an addition to up-to-date therapies. Hammache et al. implicitly emphasize this fact in two of their comments. First, they claim that a circular catheter was used in both the Conventional and DE-CMR groups, so that the DE-CMR group could also benefit from the circular catheter. This probably holds true, since our study was planned to study the additive effect of DE-CMR on top of current ablation techniques, including a circular catheter. Second, few patients in both groups took advantage of contact force (CF) catheters. Similarly, most studies assessing CF catheters were conducted in the absence of DE-CMR data. We feel that both issues exemplify the rapid development of medical technology that continuously uncovers yet unmet needs. On the one hand, testing the use of DE-CMR as a standalone tool to localize and ablate gaps in re-do procedures, avoiding circular catheters, might be tested in subsequent studies. On the other hand, we should bear in mind that CF catheters and DE-CMR might not be mutually exclusive. Indeed, deeper and more durable lesions achieved by CF catheters6 may benefit from a comprehensive and more accurate localization of ablation gaps in re-do procedures. Eventually, improving diagnosis, risk stratification,7 ablation tools and techniques1 is pivotal to reach a truly tailored therapy and improve outcomes in AF. DE-CMR evolves as a central tool in the multimodal approach to tissue characterization that could guide electrophysiological procedures, as highlighted in our study1 and Hammache et al. comments.2 The present work has been partially funded by research grants from the European Commission (CATCHME project, contract agreement 633196), Instituto de Salud Carlos III (PI16/00435; PI19/00443; PI19/00573); Fundació la Marató TV3 (reference 20152730) and CERCA Programme/Generalitat de Catalunya.
No takes yet. Share an insight, caveat, or question.
Quinto et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: