Why the study?
Does DE-CMR-guided Re-PVI improve freedom from atrial arrhythmia compared to conventional approach in patients undergoing redo-ablation for atrial fibrillation?
Does DE-CMR-guided Re-PVI improve freedom from atrial arrhythmia compared to conventional approach in patients undergoing redo-ablation for atrial fibrillation?
Answers are grounded in this paper and cite their sources.
This editorial highlights potential methodological concerns regarding patient overlap in a study suggesting DE-CMR guidance improves outcomes in AF redo-ablation.
We read with interest the article recently published by Quinto et al.1 in EP Europace. This retrospective case–control study aimed to analyse whether using delayed enhancement cardiac magnetic resonance imaging (DE-CMR) to localize veno-atrial gaps in atrial fibrillation (AF) redo-ablation improved outcomes during follow-up. From June 2012 to November 2014, the authors included 35 case patients who underwent a Re-PVI guided by DE-CMR and 35 control patients who underwent a Re-PVI following the conventional circular-guided approach without CMR. At 2-year follow-up, more patients in the DE-CMR-guided group remained free from atrial arrhythmia compared with the conventional group. Firstly, this study closely matches the design and results of a previous study conducted by the same team and published in 2014 on 15 cases compared to 15 control patients.2 The authors did not specify if these 15 patients are included in the present analysis, thus limiting the original...
No takes yet. Share an insight, caveat, or question.
Hammache et al. (2021) studied this question.