Answers are grounded in this paper and cite their sources.
Contrasting two similar buildings one of which had a vibration problem at the lounge adjoining to an aerobics studio, the cause of the problem was explained by the result of measurements and evaluation of habitability. A countermeasure based on simulation results settled the problem. A study of how force is employed to the floor demonstrates that the floor vibration from aerobics with dozens of participants can be predicted accurately by the response to the force of around eight people in phase and multiplying it by the root of the number of participants divided by the number of people in phase. The dynamic load factors for aerobics are also examined to be nearly equal to the factors of literature.
No takes yet. Share an insight, caveat, or question.
Ken-ichi Narita (2004) studied this question.