Why the study?
Tomographic imaging of the heart is expected to be superior to planar imaging, but the quality and utility of MIBG SPECT in postinfarction HF patients without DM qualified for primary prevention ICD was unclear.
Does [123I]I-MIBG cardiac SPECT imaging provide acceptable image quality in postinfarction nondiabetic HF patients qualified for ICD?
Does [123I]I-MIBG cardiac SPECT imaging provide acceptable image quality in postinfarction nondiabetic HF patients qualified for ICD?
MIBG SPECT imaging has limited utility in postinfarction HF patients qualified for ICD due to unacceptable or low image quality in approximately half of the patients.
Answers are grounded in this paper and cite their sources.
May limit MIBG SPECT utility for ICD stratification in postinfarction HF; leaves open protocol optimization or alternative imaging research.
OBJECTIVE: I]I-metaiodobenzylguanidine (MIBG) enables assessment of the cardiac adrenergic nervous system. Tomographic imaging of the heart is expected to be superior to planar imaging. This study aimed to determine the quality and utility of MIBG SPECT in the assessment of cardiac innervation in postinfarction HF patients without DM, qualified for implantable cardioverter defibrillator (ICD) in primary prevention of sudden cardiac death. METHODS: Consecutive patients receiving an ICD on the basis of contemporary guidelines were prospectively included. Planar MIBG studies were followed by SPECT. The essential analysis was based on visual assessment of the quality of SPECT images ("high", "low" or "unacceptable"). The variables used in the further analysis were late summed defect score for SPECT images and heart-to-mediastinum rate for planar images. MIBG images were assessed independently by two experienced readers. RESULTS: Fifty postinfarction nondiabetic HF subjects were enrolled. In 13 patients (26%), the assessment of SPECT studies was impossible. In addition, in 13 of 37 patients who underwent semiquantitative SPECT evaluation, the assessment was equivocal. Altogether, in 26/50 patients (52%, 95% confidence interval 38-65%), the quality of SPECT images was unacceptable or low and was limited by low MIBG cardiac uptake and by comparatively high, interfering MIBG uptake in the neighboring structures (primarily, in the lungs). CONCLUSIONS: The utility of MIBG SPECT imaging, at least with conventional imaging protocols, in the qualification of postinfarction HF patients for ICD, is limited. In approximately half of the postinfarction HF patients, SPECT assessment of cardiac innervation can be impossible or equivocal, even without additional damage from diabetic cardiac neuropathy. The criteria predisposing the patient to good-quality MIBG SPECT are: high values of LVEF from the range characterizing the patients qualified to ICD (i.e., close to 35%) and left lung uptake intensity in planar images comparable to or lower than heart uptake.
No takes yet. Share an insight, caveat, or question.
Teresińska et al. (2021) studied this question.