Why the study?
Does implanting acrylic cement into the femoral shaft cause a fall in systemic arterial blood pressure during hip arthroplasty?
Does implanting acrylic cement into the femoral shaft cause a fall in systemic arterial blood pressure during hip arthroplasty?
Answers are grounded in this paper and cite their sources.
Implanting acrylic bone cement into the femoral shaft during hip arthroplasty is associated with a rapid fall in systemic arterial blood pressure.
A pilot study has shown that there is usually but not invariably a fall in systemic arterial blood pressure within 90 seconds of implanting acrylic cement into the femoral shaft during hip arthroplasty. There is usually no change in arterial blood pressure on implanting acrylic cement into the acetabulum. The observed hypotension may be due to absorption of monomer or additives into the circulation, but the role of other factors needs investigation.
No takes yet. Share an insight, caveat, or question.
Phillips et al. (1971) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: