Answers are grounded in this paper and cite their sources.
Detection of stator winding inter-turn insulation failure at early stages is crucial for promoting safe and economical use of induction motors in industrial applications. Whereas major insulation failures involving larger percentages of winding are easily discernible from magnitude of supply current, minor inter-turn insulation failures involving less than 5% of turns often go undetected. The present contribution reports experimental results of minor faults due to inter-turn insulation failures in stator windings of induction motor under different loading conditions being analyzed using data and signal processing tools combining Park's Transform and Cross Wavelet Transform. Rough Set Theory (RST) based classifier has been used for fault severity monitoring.
No takes yet. Share an insight, caveat, or question.
Das et al. (2011) studied this question.