Key result
Multiplex RRT-PCR demonstrated sensitivity varying by target between 150 gene copies for TAstV-2 alone and 2200 gene copies for TCV, with cloacal swabs showing similar sensitivity to intestinal samples.
A multiplex RRT-PCR assay was successfully developed for the sensitive and simultaneous detection of three viruses associated with Poult Enteritis Complex in turkeys.
Answers are grounded in this paper and cite their sources.
Cloacal swabs may enable sensitive multiplex detection of turkey enteritis viruses; leaves open prospective field validation before clinical adoption.
Poult enteritis complex (PEC) is an economically important disease of young turkeys characterized by diarrhea, poor weight gain, and, in some cases, high mortality. Although PEC is considered to be a polymicrobial disease, numerous viruses, including turkey coronavirus (TCV), turkey astrovirus type 2 (TAstV-2), and avian reoviruses (ARVs), have been associated with PEC-like disease. Real-time reverse transcription-polymerase chain reaction (RRT-PCR), a highly sensitive and specific detection method for viral RNA, was developed in a multiplex format for the simultaneous detection of TAstV-2 and TCV and for the detection of two genetic types of ARV. Assay sensitivity was determined using in vitro transcribed RNA and varied by target between 150 gene copies for TAstV-2 alone and 2200 gene copies for TCV when multiplexed. Virus detection was evaluated with samples collected from poults inoculated at 1 day of age with each of the viruses. Cloacal swabs and intestinal samples were obtained at 1, 2, 3, 4, 6, 9, 14, 17, and 21 days after inoculation, processed, and tested for virus detection by RRT-PCR Cloacal swabs from TAstV-2- and TCV-infected poults were shown to have sensitivity for virus detection similar to that of intestinal samples when compared directly. ARV detection by RRT-PCR was compared with virus isolation and had similar sensitivity.
No takes yet. Share an insight, caveat, or question.
Spackman et al. (2005) studied Poult enteritis complex (PEC). Multiplex Real-Time Reverse Transcription-Polymerase Chain Reaction (RRT-PCR) vs. Virus isolation / Intestinal samples was evaluated on Assay sensitivity and virus detection. Multiplex RRT-PCR demonstrated sensitivity varying by target between 150 gene copies for TAstV-2 alone and 2200 gene copies for TCV, with cloacal swabs showing similar sensitivity to intestinal samples.
Synapse has enriched 10 related papers. Consider them for comparative context: