Does fibrillatory wave size on electrocardiogram differentiate between rheumatic heart disease and arteriosclerotic heart disease in patients with atrial fibrillation?
Does fibrillatory wave size on electrocardiogram differentiate between rheumatic heart disease and arteriosclerotic heart disease in patients with atrial fibrillation?
This historical study aimed to determine if fibrillatory wave amplitude on ECG could differentiate between rheumatic and arteriosclerotic heart disease in patients with atrial fibrillation.
Answers are grounded in this paper and cite their sources.
Fibrillatory wave amplitude assessment in AF remains unproven for etiology differentiation; leaves open its diagnostic utility in contemporary cohorts.
LITTLE has been written on the analysis of the fibrillatory waves (f waves) of the electrocardiogram in atrial fibrillation in the differential diagnosis be- tween rheumatic heart disease with mitral involvement and arteriosclerotic heart disease.In 1915 Hewlett and Wilson' reported one patient with atrial fibrillation whose f waves were larger, but attached no significance to the finding.Cookson2 in 1929 stated that the size of the f waves were "medium to large" in rheumatic heart disease and "medium to small" in other types of heart disease.In 1956 Osol3 found the voltage of the f waves greater in patients with rheumatic heart dis- ease than in those with arteriosclerotic heart disease.The purpose of this investigation was to determine whether the differences in volt- age of the f waves are sufficiently consistent to be useful in differentiating rheumatic heart disease and arteriosclerotic heart disease when atrial fibrillation is present. Methods All electrocardiograms taken at the University Hospital (Firmin Desloge Hospital) of the SaintLouis University School of Medicine for the last 3 years were reviewed and all the tracings of all patients who showed atrial fibrillation at any time during the course of their disease were selected for this study and analyzed without previous knowledge of the clinical diagnosis.All the electro- cardiograms were standardized so that 1-millivolt input produced a 10-mm.deflection of the stylus and were recorded on Sanborn Visocardiette ma- chines.We measured the f waves from trough to peak, considering the trough preceding the peak of the wave.As illustrated in figure 1 the center of the inscription line was taken for the measure- ment.The f waves measuring more than 1/2 mm. in amplitude were considered coarse.Fine f waves
No takes yet. Share an insight, caveat, or question.
Thurmann et al. (1962) studied this question.