Why the study?
Does the presence of QRS alternans during ventricular tachycardia predict failure of antitachycardia pacing and lack of spontaneous termination in patients with implantable defibrillators?
Does the presence of QRS alternans during ventricular tachycardia predict failure of antitachycardia pacing and lack of spontaneous termination in patients with implantable defibrillators?
QRS alternans during ventricular tachycardia is a relatively common finding that may predict failure of antitachycardia pacing and lack of spontaneous termination.
Answers are grounded in this paper and cite their sources.
QRS alternans in VT was associated with higher ATP failure and absent spontaneous termination; hypothesis-generating for ICD programming, needs prospective validation.
Although the value of T wave alternans as an index of electrical instability has been extensively investigated, little is known about QRS alternans during VT. Intracardiac electrograms of 111 episodes of spontaneous monomorphic regular VT retrieved from implantable defibrillators in 25 patients were retrospectively selected. Three beat series, representing the total amplitudes and amplitudes from baseline to summit and from baseline to lower point of 16 or 32 successive QRS complexes before deliverance of electrical therapy were generated for each episode. Spectral analysis was then performed using the fast Fourier transform. VT was considered as alternans if the magnitude of the spectral power at the 0.5-cycle/beat frequency was greater than the mean +/- 3 SD of the noise in at least one of the three spectral curves. QRS alternans was present in 23 (20%) of 111 episodes and in 9 (36%) of 25 patients. Alternans was not related to the VT cycle length, QRS duration, QRS amplitude, signal amplification, nor to clinical variables. Alternans was more frequently detected in unipolar configuration and when a higher number of complexes was included in analysis. Failure of antitachycardia pacing was more frequent in case of alternans VT (50% vs 75% success in nonalternans VT, P = 0.05). Spontaneous termination before deliverance of therapy occurred in 16 non-alternans VT but never in alternans episodes (P = 0.02). Alternans in QRS amplitude is a relatively common finding during VT and could be associated with failure of antitachycardia pacing and lack of spontaneous termination. Lower efficacy of electrical therapies in case of QRS alternans must be confirmed in a way to improve the effectiveness of antitachycardia pacing.
No takes yet. Share an insight, caveat, or question.
Maury et al. (2002) studied this question.