Why the study?
It was unknown whether the higher mortality associated with antitachycardia pacing failure and shock termination in heart failure patients reflects decompensated heart failure.
Do ICD heart failure diagnostics predict the failure of antitachycardia pacing and the need for shock in heart failure patients with monomorphic ventricular tachycardia?
Do ICD heart failure diagnostics predict the failure of antitachycardia pacing and the need for shock in heart failure patients with monomorphic ventricular tachycardia?
Device diagnostics associated with decompensated heart failure, such as higher atrial fibrillation burden and lower patient activity, can identify MMVT events that fail ATP and require shock.
Answers are grounded in this paper and cite their sources.
May flag MMVT events needing shocks in HF; leaves open prospective validation before guiding device therapy.
Background Among heart failure patients with implantable cardioverter defibrillators (ICDs), monomorphic ventricular tachycardia (MMVT) failing antitachycardia pacing (ATP) and terminated by shock renders higher mortality as compared to MMVT terminated by ATP only. It is unknown if the higher mortality in ATP failure reflects decompensated heart failure. Objective It was the purpose of the present study to determine if ICD heart failure diagnostics can predict the failure of ATP and the need to shock to terminate MMVT. Methods This was a single‐center retrospective review of 103 consecutive patients with Medtronic ICDs who had MMVT and received ICD therapy. Heart failure diagnostics preceding each MMVT event were reviewed including atrial fibrillation burden, patient activity, night heart rate, heart rate variability, Optivol ® fluid index, and MMVT heart rate. Results A total of 452 MMVT events were analyzed, of which 23% required shock. Compared to MMVT that responded to ATP, MMVT that failed ATP and required shock had significantly faster heart rates and higher atrial fibrillation burden. Patient activity, night heart rate, heart rate variability, and OptiVol ® fluid index were similar between ATP responsive MMVT events and those that failed ATP. In a multivariate analysis adjusting for baseline characteristics, higher atrial fibrillation burden and lower patient activity were associated with ATP failure and shock termination. Conclusion Device diagnostics associated with decompensated heart failure identified MMVT events that failed ATP and necessitated shock.
No takes yet. Share an insight, caveat, or question.
Al‐Damluji et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: