Key result
Appropriate ICD therapy was associated with increased mortality compared to no episodes, with hazard ratios of 1.46 for ATP-only, 2.11 for single shock, and 2.55 for multiple shocks.
Why the study?
Do ICD therapies (ATP or shocks) increase the risk of mortality in patients with ICDs?
Observational (n=2,255)
Do ICD therapies (ATP or shocks) increase the risk of mortality in patients with ICDs?
Hazard Ratio: 1.46 (95% CI 1.05–2.02)
p-value: p=0.023
Appropriate ICD therapies, including both ATP and shocks, are associated with an increased risk of all-cause mortality, whereas inappropriate therapies are not.
Appropriate ICD therapies may mark higher-risk patients; leaves open whether therapies are causal or prognostic markers.
BACKGROUND: Analyses from primary prevention trials on implantable cardioverter defibrillator (ICD) therapy have shown an association between shocks and increased mortality. Recent data suggest a similar association with antitachycardia pacing (ATP). OBJECTIVE: The OMNI study is an observational study of pacemaker and ICD use. We aim to examine associations between ICD therapies and mortality in this setting. METHODS: A total of 2,255 OMNI patients with ICDs were included. Treated episodes were classified as appropriate or inappropriate. Patients were assigned into 1 of 3 groups depending on whether the episode required ATP only, single shock, or multiple shocks, and then followed for all-cause mortality. Additionally, we aimed to determine the frequency with which inappropriate ATP precipitated ventricular arrhythmias that led to shock, since this has been suggested as a mechanism of harm. RESULTS: Over a mean follow-up of 39 ± 19 months, there were a total of 470 deaths (21%). Compared to patients with no treated episodes, patients with appropriate therapy had greater risk of death. Hazard ratios were 1.46 (95% confidence interval [CI] 1.05-2.02; P = 0.023) for the ATP-only group, 2.11 (95% CI 1.51-2.96; P < 0.001) for the single-shock group, and 2.55 (95% CI 1.43-4.57; P = 0.002) for the multishock group. There was no significant association between any type of inappropriate therapy and increased mortality. We identified only 7 instances of inappropriate ATP precipitating ventricular arrhythmia resulting in shock. CONCLUSIONS: Patients receiving appropriate therapy of all types had increased mortality compared to those with no episodes. Furthermore, inappropriate ATP rarely precipitates ventricular arrhythmias.
No takes yet. Share an insight, caveat, or question.
Sun et al. (2015) conducted an observational in Patients with implantable cardioverter defibrillators (ICDs) (n=2,255). Appropriate ICD therapy (ATP only, single shock, or multiple shocks) vs. No treated episodes was evaluated on All-cause mortality (HR 1.46, 95% CI 1.05-2.02, p=0.023). Appropriate ICD therapy was associated with increased mortality compared to no episodes, with hazard ratios of 1.46 for ATP-only, 2.11 for single shock, and 2.55 for multiple shocks.