Key result
Circumferential mitral annular calcification reaching the anterior annulus was associated with higher 30-day all-cause mortality compared to less severe calcification (13% vs 2%).
Why the study?
The study sought to report the calcification pattern of the mitral valve annulus and its implications for procedural and safety outcomes in transcatheter aortic valve implantation.
Does extensive mitral annular calcification worsen procedural and safety outcomes in patients undergoing transcatheter aortic valve implantation?
Cohort (n=305)
No
Does extensive mitral annular calcification worsen procedural and safety outcomes in patients undergoing transcatheter aortic valve implantation?
Extensive mitral annular calcification in TAVI patients is associated with increased risks of paravalvular leaks, conduction disorders, and higher 30-day mortality, suggesting a need for careful prosthesis selection.
OBJECTIVES: This study sought to report the calcification pattern of the mitral valve annulus and its implications for procedural and safety outcomes in transcatheter aortic valve implantation. METHODS: Between November 2018 and September 2019, a total of 305 patients had transcatheter aortic valve implants at our institution. The extent of calcification of the mitral valve annulus was analysed, and the impact on safety outcomes was evaluated. RESULTS: The prevalence of mitral annular calcification (MAC) was 43%. Calcification of the mitral valve annulus was either less than or at least one-third of the posterior annulus (34% and 32%), the whole posterior annulus (28%) or the extension to the attachment of the anterior leaflets (7%). Severe circumferential MAC revealed moderate paravalvular leaks in 5/8 (63%) patients and was associated with right branch bundle block [odds ratio (OR) 2.01 (0.39-3.06); P = 0.098] and low cardiac output [OR 3.12 (1.39-7.04); P = 0.033]. Subannular calcification at the anterolateral trigonum represented a risk factor for left ventricular outflow tract injury [OR 3.54 (1.38-8.27); P = 0.001] in balloon-expandable valves, associated with relevant rhythm disorders [OR 2.26 (1.17-5.65); P = 0.014] and female gender (7/8, 88%). The 30-day all-cause mortality in circumferential MAC reaching into the anterior annulus (grade IV) compared to patients with less MAC (grade I-III) was 13% vs 2% with a mean valve size of 24.6 vs 25.7 mm. CONCLUSIONS: Extensive MAC was associated with moderate paravalvular leaks, with implications for the prosthesis size and survival in transcatheter aortic valve implants. In severe MAC, we recommend implanting oversized self-expandable prostheses, the goal being to reduce the risk of right branch bundle block and paravalvular leaks. SUBJ COLLECTION: 122, 125.
No takes yet. Share an insight, caveat, or question.
Haensig et al. (2021) conducted a cohort in Transcatheter aortic valve implantation (n=305). Severe circumferential mitral annular calcification (grade IV) vs. Less severe mitral annular calcification (grade I-III) was evaluated on 30-day all-cause mortality. Circumferential mitral annular calcification reaching the anterior annulus was associated with higher 30-day all-cause mortality compared to less severe calcification (13% vs 2%).