Key result
Automated motion correction and co-registration improved the qualitative assessment of cardiac MR T1 maps in 59% of cases and ECV maps in 67% of cases, reducing poor-quality T1 maps from 23% to 2%.
Why the study?
Does automated motion correction and co-registration improve the qualitative assessment and reproducibility of cardiac MR T1 and ECV measurements in patients with diverse cardiac pathologies?
Observational (n=21)
No
Does automated motion correction and co-registration improve the qualitative assessment and reproducibility of cardiac MR T1 and ECV measurements in patients with diverse cardiac pathologies?
Automated motion correction and co-registration significantly improves the image quality and reproducibility of cardiac MR T1 and ECV mapping, facilitating more reliable non-invasive assessment of myocardial fibrosis.
May enhance fibrosis assessment reliability in clinical CMR; leaves open prospective validation of diagnostic impact.
OBJECTIVE: Our aim was to investigate the technical feasibility of a novel motion compensation method for cardiac magntic resonance (MR) T1 and extracellular volume fraction (ECV) mapping. MATERIALS AND METHODS: Native and post-contrast T1 maps were obtained using modified look-locker inversion recovery (MOLLI) pulse sequences with acquisition scheme defined in seconds. A nonrigid, nonparametric, fast elastic registration method was applied to generate motion-corrected T1 maps and subsequently ECV maps. Qualitative rating was performed based on T1 fitting-error maps and overlay images. Local deformation vector fields were produced for quantitative assessment. Intra- and inter-observer reproducibility were compared with and without motion compensation. RESULTS: Eighty-two T1 and 39 ECV maps were obtained in 21 patients with diverse myocardial diseases. Approximately 60% demonstrated clear quality improvement after motion correction for T1 mapping, particularly for the poor-rating cases (23% before vs 2% after). Approximately 67% showed further improvement with co-registration in ECV mapping. Although T1 and ECV values were not clinically significantly different before and after motion compensation, there was improved intra- and inter-observer reproducibility after motion compensation. CONCLUSIONS: Automated motion correction and co-registration improved the qualitative assessment and reproducibility of cardiac MR T1 and ECV measurements, allowing for more reliable ECV mapping.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2017) conducted an observational in Diverse cardiac pathologies (n=21). Automated motion correction and co-registration vs. Uncorrected images was evaluated on Quality improvement of T1 maps. Automated motion correction and co-registration improved the qualitative assessment of cardiac MR T1 maps in 59% of cases and ECV maps in 67% of cases, reducing poor-quality T1 maps from 23% to 2%.